58
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
No.
Name
Range
Factory Setting Ref. page
o422
Function during warning time
1 - 2
1
1
Output signal deactivated during warning
2
Output signal as configured in o410-o413
o423
Flashing frequency
0.1-2.0 sec
0.5
o430
Alarm if there is an error as configured in
o431-o439. The alarm is activated for at least the
time set in this channel.
0.00-9.59min
0.00
o431
Alarm for faulty safety edge. Time as in o430.
0 - 1
0
0
Constant signal
1
Active
o432
Alarm for error message in display
0 - 1
0
0
Constant signal
1
Active
o433
Alarm if stop circuit interrupted
0 - 1
0
0
Disabled
1
Constant signal
o434
Alarm if door open
0 - 1
0
0
Disabled
1
Constant signal
o435
Alarm if door is in mid position
0 - 1
0
0
Disabled
1
Constant signal
o436
Alarm if door is in closed position
0 - 1
0
0
Disabled
1
Constant signal
o437
Alarm if vehicle loop 1 is activated
0 - 1
0
0
Disabled
1
Constant signal
o438
Alarm if vehicle loop 2 is activated
0 - 1
0
0
Disabled
1
Constant signal
o439
Alarm if photocell interrupted
0 - 1
0
0
Disabled
1
Constant signal
o483
Inversion of contact function for output
1 - 2
1
1
Normally open, NO
2
Normally closed, NC