![FAAC DAAB EP104 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053040.webp)
40
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
General time channels
No.
Name
Range
Factory Setting Ref. page
C401
Running time readout motor 1
000-999 sec
C402
Running time readout motor 2
000-999 sec
C403
Set limited running time
001-999 sec
001
C411
Time readout, opened to closed position motor 1,
used for C412
00.0-99.9 sec
C412
Set limited opening motor 1
00.3-99.9 sec
05.0
C413
Time readout, opened to closed position motor 2,
used for C414
00.0-99.9 sec
C414
Set limited opening motor 2
00.3-99.9 sec
05.0
C422
Run-on time following limit switch open, motor 1
0.00-4.99 sec
0.00
C423
Run-on time following limit switch closed , motor 1 0.00-4.99 sec
0.00
C432
Run-on time following limit switch open, motor 2
0.00-4.99 sec
0.00
C433
Run-on time following limit switch closed , motor 2 0.00-4.99 sec
0.00
S
C436 Type of stop during run-on time when closing,
subordinated to C448
0 - 3
3
0
Time
1
Time or load guard
2
Time or safety edge
3
Time, load guard or safety edge
S
C448 Safety edge reversal during run-on time, C421,
C422, C431, C432
0 - 2
2
0
Function disabled
1
Safety edge reversal during run-on time
2
Safety edge reversal during run-on time and during the time in C492
C460
Delay of open motor 2 and close motor 1. Used
with magnetic locks or if the door halves overlap
0.1-9.9 sec
0.1
C470
Delay before first motor starts, used for magnetic
locks that need to lose residual magnetisation
0.00-0.99 sec
0.00
C492
Reversal delay if PHOTO, SL1 or SL2 or control
signal are activated
0.1-4.0 sec
0.8
S
C493 Reversal delay if safety edge or load guard are
activated
0.03-2.00 sec
0.10
S
C494 Reversal time for protection in the opening
movement, safety edge and load guard
0.1-2.0 sec
1.0