38
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Load guard and motor settings
No.
Name
Range
Factory Setting Ref. page
S
C200 Load guard function
0 – 4
3
0
Disabled Service and troubleshooting only
1
Reversal when closing, stop when opening
2
Stop when closing and reversal when opening
3
Reversal when closing and opening
4
Stop when closing and opening
S
C201 Low current limit active, inactive only with
frequency converter (C202 = 4).
0 – 1
1
0
Inactive
1
Active
S
C202 Type of power supply
0 - 5
0
0
3x400 V with neutral
1
3x230 V without neutral
2
1x230 V with neutral, asymmetric
3
3x400 V without neutral (see separate instructions)
4
Frequency converter (see separate instructions)
5
1x230 V with neutral, symmetric
S
C211 Load guard delay
0.01-2.50 sec
0.06
S
C212 Load guard connection delay when starting, all
starts
0.1-2.5 sec
1.0
S
C221 Motor protection delay
3.0-5.0 sec
3.0
S
C230 Set motor power readout for personal protection,
motor 1
0.00 and 0.12-0.35
kW
0.20
C231
Motor power readout, motor 1
0.00-1.99 kW
S
C232 Set load guard limit for motor 1 opening
0.05-1.99 kW
0.60
S
C233 Set load guard limit for motor 1 closing
0.05-1.99 kW
0.60
S
C240 Set motor power readout for personal protection,
motor 2
0.00 and 0.12-0.35
kW
0.20
C241
Motor power readout, motor 2
0.00-1.99 kW
S
C242 Set load guard limit for motor 2 opening
0.05-1.99 kW
0.60
S
C243 Set load guard limit for motor 2 closing
0.05-1.99 kW
0.60
C251
Motor current readout, motor 1
0.0-20.0A
S
C252 Set normal value for motor current opening, motor
1
0.0 and 0.5-6.0A
1.0
S
C253 Set normal value for motor current closing, motor 1 0.0 and 0.5-6.0A
1.0
C261
Motor current readout, motor 2
0.0-20.0A
S
C262 Set normal value for motor current opening, motor
2
0.0 and 0.5-6.0A
1.0
S
C263 Set normal value for motor current closing, motor 2 0.0 and 0.5-6.0A
1.0
C271
Power factor readout motor 1
0.00-0.99 cos
φ