9
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Operation
• General
!
Anyone installing or modifying the EP104 must have documented knowledge and understanding of its functions, and
also knowledge of installing control systems for the application to be used.
Take care when operating internal buttons to avoid touching live components.
The unit may only be connected by a qualified electrician, who accepts responsibility for ensuring that the electric connections
are in accordance with the applicable standards and this instruction manual.
Anyone commissioning the EP104 must have documented knowledge and understanding of its functions, and knowledge of
commissioning control systems for the application to be used.
• Service and maintenance
!
The EP104 requires regular inspection of the external safety features, such as safety edge, stop buttons, photocells, load
guards and safety loops. The enclosure, cabling and installation must also be checked. This inspection must be carried
out at least twice a year.
Whenever work is carried out in or near the control unit, the power supply to the EP104 must be disconnected with a locked
main switch.
• Resetting/replacing tripped fuses
If the fuse protecting the power supply to the automatic control unit trips, FAAC Nordic AB recommends following these
steps to reset/replace it.
• Switch off the main switch to the automatic control unit.
• Decouple the motor winder.
• Reset or replace the fuse.
• Switch on the main switch to the automatic control unit.
• Check that none of the motor winders start before receiving the control signal.
• Check that the motor winders can be started and stopped from the control buttons.
• If the motor winder cannot be stopped, contact FAAC Nordic AB.
Содержание DAAB EP104