![FAAC DAAB EP104 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053011.webp)
11
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Installing the EP104 PCB
If you are installing the PCB in a dedicated enclosure, you must follow the instructions below – otherwise the requirements of
the applicable EU directive will not be met, FAAC Nordic's declaration of conformity will not be valid and the product will
not be authorised for use. If the PCB is installed elsewhere, the installer is responsible for obtaining CE approval of the control
system in its entirety.
• Authorisation
!
Persons installing the PCB in an enclosure must be trained and authorised for the particular task.
• Enclosure
The PCB must be installed in an enclosure designed for the surrounding environment, and must protect the electronics from
moisture, dust and contact.
!
The enclosure must provide protection to class IP54 or better and must be designed for screw fixing to a wall or bracket.
For outdoor use or if there is a risk of condensation in the enclosure, a heating element must be used.
• Installing the PCB
The PCB must be secured to a metal plate. The PCB dimensions are shown below.
Use the screws, spacers and washers provided to fix the PCB as illustrated.
!
If the fixing plate is painted, scrape off the paint around the holes to ensure good contact between the spacers and the
plate.
Fit the earth bar to the fixing plate, for connecting the external earth.
12.7
188
223.5
30.4
12.7
189.2
163.8
Metal screw M4
Control board
Metal spacer, at least 10mm
2 metal washers
Mounting plate
with M4-winding
Earth Terminal
Ø 4.5 (4x)
Содержание DAAB EP104