31
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Functions using add-in cards
Add-in cards can be installed in the EP104 for access to extra functions. The add-in cards are DB401 for programmable
outputs, DB402 for a vehicle detector, DB403 (DBR1 system) for four programmable wireless inputs, DB404 (FAAC SLH
system) for one programmable input and DB406 for motor control using a frequency converter.
Follow the instruction manual supplied with the add-in card when installing the card in the EP104.
• Programmable outputs, o channels
You can use the DB401 add-in card to access four programmable outputs in the EP104.
Programmable outputs 1 - 3
The instructions are identical for these three programmable outputs, apart from the channel number – output 1 has channel
number o1nn, output 2 has channel number o2nn, etc. The settings below are for output 1.
Activate programmable output 1 by setting o100 to the desired function. A value of 0 means that the output is disabled
(open) regardless of the settings of other channels.
If you set the value to 1, the output can be used as a traffic light signal based on the position indicator. Movement and
warning time signals are also available with this setting. The value 2 is for presence detection in the vehicle loop, the value
3 is for motor locks, and the value four turns the output into an alarm output.
Channel o110 Open position
Set to 1 for a constant signal in the open position.
Channel o111 Mid position
Set to 1 for a constant signal in the mid position.
Channel o112 Closed position
Set to 1 for a constant signal in the closed position.
Example for a green light: o110 = 1, o111 = 0, o112 = 0.
Example for a red light: o110 = 0, o111 = 1, o112 = 1.
Channel o113 Movement
Use this channel to specify the function during movement. The function will be active as soon as the door starts moving.
See the channel reference for the available options. Only output 4 is able to send a flashing signal.
Channel o120 Warning time before start The time can be set to 0.00 – 9.59 minutes. 0.00 means the function is disabled
and the function is defined in o121.
Channel o121 Warning function in combination with channel o120
Set the value to 1 for a constant signal before an opening movement, 2 for a constant signal before a close signal, parking
and automatic closing, 3 for a signal within all control signals.
Channel o130 Delay for alarms specified in o131 and o132. The alarm is delayed by the specified time of 0.00 – 9.59
minutes. The factory setting is 0.00.
Channel o131 Alarm for faulty safety edge
This channel is available if the output card is used as an alarm output. The channel sends a signal if the safety edge has been
activated for longer than the time specified in o130.
Channel o132 Alarm for error message in display
If the value is set to 1, a signal is sent if an error message appears in the display for longer than the time specified in o130.
Channel o191 Function when LOOP2, LOOP2 or PHOTO is activated:
Use this channel to specify the type of presence detection you want to use with the vehicle loop. See the channel reference
for the available options.
You can set the output to normally open or normally closed by changing the value in o183 to:
The value 1 is for normally open (NO) and the value 2 is for normally closed (NC).