![FAAC DAAB EP104 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053018.webp)
18
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
• Indicators
To simplify commissioning and troubleshooting, LEDs are provided to indicate faults and the status of input signals, as shown
in the table below.
Colour
Indication
Active when
Yellow
START
Constant when control signal received, flashing when counting down for automatic
closing.
Red
M1
A constant LED means that the load guard settings has been exceeded, and a flashing
LED means that the load guard has been triggered for motor 1.
M2
A constant LED means that the load guard settings has been exceeded, and a flashing
LED means that the load guard has been triggered for motor 2.
S.E1
A constant LED means that the safety edge has been activated, and a flashing LED
means that the safety edge has been reset.
S.E2
A constant LED means that the safety edge has been activated, and a flashing LED
means that the safety edge has been reset.
S.E3
A constant LED means that the safety edge has been activated, and a flashing LED
means that the safety edge has been reset.
Yellow
LOOP2
Vehicle loop 2 activated
LOOP1
Vehicle loop 1 activated
L.C2
Motor 2 not finished closing, extinguished in closed position, flashing means the input
is not programmed
L.O2
Motor 2 not finished opening, extinguished in open position, flashing means the input
is not programmed
L.C1
Motor 1 not finished closing, extinguished in closed position, flashing means the input
is not programmed
L.O1
Motor 1 not finished opening, extinguished in open position, flashing means the input
is not programmed
Green
PHOTO
Photocell not activated, circuit closed
Yellow
OPEN
Signal from internal button – open
CLOSE
Signal from internal button – close
INP6
Signal at programmable input 6
INP5
Signal at programmable input 5
INP4
Signal at programmable input 4
INP3
Signal at programmable input 3
INP2
Signal at programmable input 2
INP1
Signal at programmable input 1
Green
STOP
Stop not activated, circuit closed
SAFE
Internal safety circuit – OK
Green
12V
Voltage 12VDC
24V
Voltage 24VDC
Yellow
CLOSE2
Contactor for closing movement activated – motor 2
OPEN2
Contactor for opening movement activated – motor 2
CLOSE1
Contactor for closing movement activated – motor 1
OPEN1
Contactor for opening movement activated – motor 1
Red
STOP
Stop activated, circuit interrupted (internal and external stop circuits)