![FAAC DAAB EP104 Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053071.webp)
71
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
E224
Normal power too low, motor 2
Check C240.
E318
Error in loop 1
Are the loop and connectors electrically continuous?
For more troubleshooting tips, see the instruction manual for
the vehicle detector
E319
Error in loop 2
E614
Communication error
Correct polarity in communication cables? Break in
communication cable? Correct settings in both automatic
control units? Is the external unit switched on?
E901
Error in safety edge S.E1
Contact FAAC Nordic AB.
E902
Error in safety edge S.E2
Contact FAAC Nordic AB.
E903
Error in safety edge S.E3
Contact FAAC Nordic AB.
E904
Error in limit switch sensor
Contact FAAC Nordic AB.
E905
Error in stop circuit
Contact FAAC Nordic AB.
E909
Internal watchdog triggered
Contact FAAC Nordic AB.
E910
Clock monitoring error
Contact FAAC Nordic AB.
E911
Repeated restart attempts
Short circuit in limit switch or stop circuit? After the problem
is corrected, the unit makes a new attempt to restart after 20
seconds.
E912
Incorrect checksum in flash memory
Contact FAAC Nordic AB.
E913
Memory error in RAM
Contact FAAC Nordic AB.
E914
Memory error in EEPROM
Contact FAAC Nordic AB.
E915
Incorrect EEPROM version
Contact FAAC Nordic AB.
E916
Internal test not completed in time
Contact FAAC Nordic AB.
E917
Incorrect order of execution
Contact FAAC Nordic AB.
E918
Error code list reset
E921
Contactor for motor 1 activated before the
previously activated contactor has been deactivated.
Contact FAAC Nordic AB.
E922
Contactor for motor 2 activated before the
previously activated contactor has been deactivated.
Contact FAAC Nordic AB.
E931
Stop at the same time as an open/close operation.
E932
Open operation at the same time as a close
operation.
E941
Motor 1 running in the wrong direction according
to the encoder setting.
Check that channel C110 is set to the correct side. Check the
motor is running in the right direction.
E942
Motor 2 running in the wrong direction according
to the encoder setting.
Check that channel C120 is set to the correct side. Check the
motor is running in the right direction.
E961
SE1 did not change to low during the external test. Check that the safety edge is functional, if the safety edge is
not functional, set channel C113 to 0.
E962
SE2 did not change to low during the external test. Check that the safety edge is functional, if the safety edge is
not functional, set channel C123 to 0.
E963
SE3 did not change to low during the external test. Check that the safety edge is functional, if the safety edge is
not functional, set channel C133 to 0.
E964
PHOTO did not change to low during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C343 to 0.
E971
SE1 did not change to high during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C113 to 0.
E972
SE2 did not change to high during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C123 to 0.
E973
SE3 did not change to high during the external
test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C133 to 0.
E974
PHOTO did not change to high during the
external test.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C343 to 0.
Содержание DAAB EP104
Страница 74: ......