15
ENGLISH
04
Activation of DEAD-MAN opening (command always pressed). Releasing the OPEN
command will stop operation
Y
= active
no
= disabled
05
When this function is activated, the
OPEN command
during opening will stop movement.
If parameter
06
is
no
the system is ready for opening.
If parameter
06
is
Y
the system is ready for closing.
Y
= when opening it stops
no
= disabled
06
When this function is activated, the
OPEN command
during opening reverses movement.
If parameters
05
and
06
are
no
OPEN will have no effect during opening.
Y
= when opening it reverses
no
= disabled
07
When this function is activated, the
OPEN command
during pause stops operation.
If parameters
07
and
08
are
no
OPEN resets the pause time
Y
= when in pause it stops
no
= disabled
08
When this function is activated, the
OPEN command
during pause causes closing.
If parameters
07
and
08
are
no
OPEN resets the pause time.
Y
= when in pause it closes
no
= disabled
09
When this function is activated, the
OPEN command
during closing stops operation,
otherwise it reverses movement.
Y
= stops
no
= reverses
10
Activation of DEAD-MAN closing (command always pressed). Releasing the
CLOSE
command
will stop operation
Y
= active
no
= disabled
1 1
When this function is activated, the
CLOSE command
has priority over OPEN, otherwise
OPEN has priority over CLOSE.
Y
= active
no
= disabled
12
When this function is activated, the
CLOSE command
commands closing when released.
As long as CLOSE is activated, the unit stays in closing pre-flashing.
Y
= closes when released
no
= closes immediately
13
When this function is activated, the
CLOSE command
during opening stops operation,
otherwise the CLOSE command commands reverse immediately or when opening is com
-
pleted (see also parameter
14
)
Y
= CLOSE stops
no
= CLOSE reverses
14
When this function is activated, and if parameter
13
is
no
, the
CLOSE command
commands immediate closing at the end of the opening cycle (stores CLOSE). If parameters
13
and
14
are
no
CLOSE commands immediate closing.
Y
= closes at the end of
opening
no
= immediate closing
15
When this function is activated, with the system blocked by a STOP, a
next OPEN
moves in the opposite direction. If parameter
15
is
no
it always closes.
Y
= moves in the opposite
direction
no
= always closes
16
When this function is activated, during closing, the
CLOSING SAFETIES
stop and allow
motion to resume when they are disengaged, otherwise they immediately reverse opening.
Y
= closes when disengaged
no
= immediate reverse
17
When this function is activated, the
CLOSING SAFETIES
command closing when they are
disengaged (see also parameter
18
).
Y
=
closing when FSW
is disengaged
no
= disabled
18
When this function is activated, and if parameter
17
is
Y
, the unit will wait for the
opening cycle to end before executing the closing command provided by the
CLOSING SAFETIES
.
Y
= closes at the end of
opening
no
= disabled
19
When this function is activated, during closing,
LOOP2
stops and allows motion to resume
when it is disengaged, otherwise it immediately reverses opening.
Y
= closes when disengaged
no
= immediate reverse
20
When this function is activated,
LOOP2
commands closing when it is disengaged (see also
parameter
21
).
Y
= closes if LOOP2 is clear
no
= disabled
2 1
When this function is activated, and if parameter
21
is
Y
, the unit will wait for the opening
cycle to end before executing the closing command provided by
LOOP2.
Y
= closes at the end of
opening
no
= disabled
22
When this function is activated: in case of a blackout, once electrical power has been
restored, if an OPEN command is not active the automated system recloses immediately.
Y
= active
no
= disabled
23
LOOP 1
commands opening and, once completed, it closes if disengaged (useful in case
of vehicle backing-up with consecutive loops). If disabled, when LOOP 1 is disengaged, it
does not close.
Y
= closes if LOOP1 clear
no
= disabled
24
When this function is activated, an open or close command is only carried out after
the safeties have been disengaged.
Y
= active
no
= disabled
25
A.D.M.A.P. function
When this function is activated, the result is operation of
safeties compliant with French
regulations.
Y
= active
no
= disabled
Содержание B680H
Страница 1: ...B680H ...
Страница 2: ......
Страница 4: ......
Страница 150: ...26 a b DX SX a b c Fig 10 Fig 11 M M L1 L2 L3 L1 L2 L3 Fig 12 d Fig 13 Fig 14 Fig 15 a b Fig 16 ...
Страница 151: ...27 a b c d e f g h Fig 17 L ...
Страница 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Страница 153: ...29 a b Fig 21 d e f c ...
Страница 156: ...32 Fig 31 a b c d e ...
Страница 157: ...33 Fig 32 f g ...
Страница 158: ......
Страница 163: ...5 1 2 Fig 18 ...
Страница 164: ......
Страница 165: ......