background image

AUTOMATIC BARRIERS

FA 0 0 1 2 4 - E N

English

EN

INSTALLATION AND OPERATION

G4040EZ

Содержание G4040EZ

Страница 1: ...AUTOMATIC BARRIERS FA00124 EN English EN INSTALLATION AND OPERATION G4040EZ...

Страница 2: ...COMPLIES WITH LEGAL STANDARDS THE MANUFACTURER DECLINES ALL LIABILITY FOR USE OF NON ORIGINAL PROD UCTS WHICH WOULD ALSO RESULT IN WARRANTY LOSS ALL HOLD TO RUN CON TROLS MUST BE FITTED IN PLACES FROM...

Страница 3: ...to fit accessories Intended use The automatic barrier is designed to be used in public and private parking facilities Any installation and use other than that specified in this manual is forbidden Li...

Страница 4: ...over 6 Cabinet 7 Release lock 8 Inspection hatch lock 9 Rod 10 Inspection hatch 11 Control panel 12 Boom adjustment mechanical stop 13 Lever arm 14 Gearmotor with encoder 15 EMC01 filter 16 Anchoring...

Страница 5: ...through making sure they are protected from any mechanical damage Tools and materials Make sure you have all the tools and materials you need to install the product in complete safety and in complian...

Страница 6: ...ing plate If the flooring does not provide a sturdy surface to fasten the cabinet to use a cement slab Dig a hole for the foundation frame Prepare the corrugated tubes you will need for the cables com...

Страница 7: ...on arm release the gearmotor using the key turn the transmission arm lock the motor again fasten the rod to the opposite hole in the arm invert the motor phases M and N Left Right Fill the hole with e...

Страница 8: ...ate with a screw Leave the screw loose to make it easier to insert the boom Attachment plate Intermediate plate Boom attachment cover Installing the barrier The cabinet should be installed with the in...

Страница 9: ...ice Fit the boom into the attachment cover and fasten it using the screws Cut the groove covers to the required length and insert them in the boom conduits on both sides Insert the shockproof rubber p...

Страница 10: ...with shockproof profile and 001G028401 luminous cord A A B B B C Boom with 001G0465 skirt A B B C C Boom with 001G028401 luminous cord and 001G0465 skirt A B B C C Boom with shockproof profile and 001...

Страница 11: ...er nut and lock the gearmotor again Check the spring is working properly With the boom positioned vertically the spring is not taut With the boom positioned horizontally the spring is taut Hook the ey...

Страница 12: ...0431177081 not supplied to the control signalling and safety device cables Description of parts 1 Transformer 2 Terminal board for power supply 3 Terminal board for transformer 4 Terminal board for g...

Страница 13: ...y Power supply to accessories output a 24 V AC normally a 24 V DC when the emergency batteries are operating Max power 40 W Red White Blue Orange Ferrite Transformer 230 V AC 50 60 Hz 24 V DC gearmoto...

Страница 14: ...abled from the function F 1 OPEN CLOSE INVERT step by step function from control device N O contact Keypad selector Transponder or card reader Insert the decoding card R700 for the TSP00 sensor or LT0...

Страница 15: ...the safety devices C9 immediate closure with obstacle stand by during closing Closing the boom after a vehicle has passed through the operating area of the safety devices During closing the devices al...

Страница 16: ...A The manual s contents may be edited at any time without notice Connecting the safety devices safety test At each opening and closing command the control board assesses the efficiency of the safety...

Страница 17: ...and at about 89 when open The inspection hatch must be closed when the boom opens and closes To correct the vertical position of the boom lower the boom open the inspection hatch turn the mechanical...

Страница 18: ...row keys for the submenus To increase or decrease a value use the arrow keys to exit the menu wait 10 seconds or press ESC then press ENTER to confirm Menu navigation then press ENTER Display Descript...

Страница 19: ...Parameter transfer from Master to Slave F 56 Peripheral number F 60 Sleep mode F 61 Pre flashing function F 63 Change COM speed U 1 Entering a user with an associated command U 2 Delete a single user...

Страница 20: ...19 Automatic closing time 0 Deactivated default 1 1 second 180 180 seconds The waiting time before the barrier closes automatically starts when the limit switch point is reached during opening The tim...

Страница 21: ...m booms set the percentage from 65 to 75 F49 Managing serial connection 0 Deactivated default 1 Paired 2 Alternate 3 CRP To enable paired alternate or CRP operation F50 Save data 0 Deactivated default...

Страница 22: ...boom 4 m 6 boom 6 m 8 boom 8 m To define the type of boom The choice of boom limits some of the speed slow down and calibration parameters This is so as to ensure that the operator functions correctly...

Страница 23: ...ENTER to confirm the automatic travel calibration 3 The operator closes until it reaches the limit switch point 4 then the operator opens until it reaches the limit switch point Travel calibration Bef...

Страница 24: ...firm deletion Deleting a single user When entering deleting users the flashing numbers that appear are numbers that can be used for other users you may want to enter maximum 25 users 2 Select a comman...

Страница 25: ...uration data so that they can be reused with another electronic circuit board including in another system After saving the data remove the memory roll RELEASING THE BOOM This procedure must be done wi...

Страница 26: ...he SLAVE operator Saving Follow the procedure for entering a user with the OPEN and PARTIAL PEDESTRIAN OPENING command on the MASTER panel Configuring the MASTER operator Select function F 49 Press EN...

Страница 27: ...nel of the SLAVE operator only Important Activate the F 19 function automatic closing time on the panel on both operators Saving Follow the procedure for entering a user with the OPEN and STEP BY STEP...

Страница 28: ...on The warning LED flashes quickly 4 12 Check the proper direction of travel The warning LED stays lit 13 13 Check the control devices The boom does not reach the limit switch 7 14 Replace the AF card...

Страница 29: ...e edited at any time without notice Periodic maintenance Before doing any maintenance disconnect the power supply to prevent any hazardous situations caused by the boom moving accidentally Periodic ma...

Страница 30: ...______________________________________________________ ________________________________________________________________________________________________ Fitter s stamp Name of operator Job performed on...

Страница 31: ...d from other waste for recycling Always make sure you comply with local laws before dismantling and disposing of the product DISPOSE OF THE PRODUCT RESPONSIBLY DISMANTLING AND DISPOSAL Our products ar...

Страница 32: ...ier Dosson di Casier Treviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English English Manual code FA00124...

Отзывы: