10
ENGLISH
Display
Function
Default
L2
Loop 2
Activating this parameter, any loop that is
connected to the Loop 2 input will serve as a
SAFETY/CLOSE function.
Y
Loop 2 enabled
no
Loop 2 disabled
(see note regarding Loop 1)
no
S 1
Loop 1 sensitivity
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
1 0
Maximum sensitivity
05
S2
Loop 2 sensitivity
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
1 0
Maximum sensitivity
05
Mt
Motor movement
Using the function provided by this para
-
meter makes it possible to manually move
the barrier bar, operating as
dead-man
.
Pr will open the automated system,
pressing - causes the automated system to
close.
oP
pressing
+
, open
cL
pressing
-
, close
--
St
AUTOMATED SYSTEM STATUS:
This allows you to choose whether to quit the programme
and save the data.
Y
= quit and save the data
no
= quit without saving the data
On quitting the programme, press the
F
key to display
the status of the automated system
00
Beam closed
0 1
Beam open
02
Stationary ready to open
03
Stationary ready to close
04
Automated system paused
05
Opening
06
Closing
07
Failsafe in progress
08
2-EASY device verification in progress
09
Pre-flashing then OPENS
10
Pre-flashing then CLOSES
1 1
EMERGENCY Open
You can go to St at any time by simultaneously
pressing F and -.
Displaying of the automated system status
St
is extremely
important for the installing/maintenance technician in order
to distinguish the logical processes that the board carries
out during movement.
If, for example, the automated system status is CLOSED,
the display MUST read
00
. When the OPEN command is
received, the display will change to
09
, if pre-flashing is
enabled, or directly to
05
(the OPENING movement) to then
display
0 1
once the position of gate OPEN is reached).
Example of a status sequence displayed starting from a closed barrier
00
Beam closed
05
Opening
0 1
Beam open /
04
Pause
06
Closing
The sequence does not include statuses
09
and
10
which
correspond to pre-flashing when opening and closing,
respectively.
5.2
Changing the predefined parameters set
The E680 board features six sets of pre-defined configurations that
allow rapid adapting to the size of the beam installed, making it the
starting point for a fine adjustment of the parameters. To select one
of the available configurations, you must change the parameter
dF
from the pre-set value
00
(neutral condition) to the value
corresponding to the barrier configuration (beam length, type and
number of accessories installed) shown in Tables 4 or 5 on page
24 (e.g. choose default
04
for a beam measuring 5 m in length
with foot and lights).
To complete configuration, it is necessary to exit the Basic
Configuration menu by pressing “F” until parameter
St
is reached
or by pressing “F” and “-”
Содержание B680H
Страница 1: ...B680H ...
Страница 2: ......
Страница 4: ......
Страница 150: ...26 a b DX SX a b c Fig 10 Fig 11 M M L1 L2 L3 L1 L2 L3 Fig 12 d Fig 13 Fig 14 Fig 15 a b Fig 16 ...
Страница 151: ...27 a b c d e f g h Fig 17 L ...
Страница 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Страница 153: ...29 a b Fig 21 d e f c ...
Страница 156: ...32 Fig 31 a b c d e ...
Страница 157: ...33 Fig 32 f g ...
Страница 158: ......
Страница 163: ...5 1 2 Fig 18 ...
Страница 164: ......
Страница 165: ......