Frequently Asked Questions (FAQs)
1. How do I format an address string when connecting to multiple
PLCs?
Add the PLC station number to the beginning of the address string. Ex:
PLC station is 3 and the address is V2000 the string would look like
this, 3-V2000.
2. Can I convert a project from one EZSeries Set Point Display Text
Panel type to another?
Yes, to do this simply change the panel type from one to another.
This will keep all address and message information intact. The only
exception is switching from any of the panels to the Set Point panel.
This will cause all messages and addressing to be deleted.
Note:
Switching panel types does not create a new project. If you wish to
create a new project select NEW from the FILE menu.
3. Can I connect multiple panels to a single PLC?
Yes, there are two methods of doing this. The fi rst would be to use the
multiplexer (P/N EZ-MULTIDROP). You can connect up to fi ve panels
per multiplexer, and one multiplexer per serial port. The second method
is to connect one panel per serial port.
4. What is the maximum number of messages I can have in a
project?
The maximum amount of PLC and Local messages is 256.
5.
What are Local Messages?
A Local Message is a text message that is used to provide instructions
or information to the machine operator using a hierarchical fi le structure.
The operator can scroll through these messages using the arrow keys
to fi nd information pertaining to a particular part of a process.
6. What are PLC Messages?
A PLC Message is a text message that can be triggered by the PLC
to provide the operator with important instructions, information, or
warnings. PLC Messages will be displayed for 3 seconds before they
can be cleared in order to make sure the operator has a chance to
read the message. The operator can also view the last PLC Message
displayed by pressing the
esc
key.
7. How many characters can I have per message?
The maximum number of characters per message is 20. This is true
for all messages except folder names. They are limited to 19 because
of the plus “+” or minus “-” sign displayed at the beginning of the folder
Содержание EZ-220
Страница 27: ...23 EZ TEXT M E Text Panel Hardware Manual Connections and Wiring EZSeries Text Panel Application...
Страница 46: ...42 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Страница 65: ...61 EZ TEXT M E Text Panel Hardware Manual...
Страница 80: ...76 EZ TEXT M E Text Panel Hardware Manual...
Страница 81: ...77 EZ TEXT M E Text Panel Hardware Manual...
Страница 88: ...84 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Страница 100: ...96 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Страница 114: ...B 8 Text Panel Hardware Manual Omron C200 C500 RS 232 P N EZP OMRON CBL Siemens S7 MPI Adaptor P N EZP S7MPI CBL...
Страница 118: ...B 12 Text Panel Hardware Manual Idec MicroSMART PLC RS232 8 pin Mini DIN Male P N EZP IDECS CBL...
Страница 120: ...B 14 Text Panel Hardware Manual This page intentionally left blank...
Страница 150: ...I 8 EZ TEXT M Text Panel Hardware Manual This page intentionally left blank...