44
EZ-TEXT-M-E
Text Panel Hardware Manual
SETUP Mode
In order to download the program to the
EZSeries Set Point Display Text Panel using
the EZSeries Set Point Display Text Panel
Programming Software, you must be in the
Setup Mode. Setup Mode is also where
you will
adjust the display contrast
of the EZSeries Set Point Display Text
Panel.
The EZSeries Set Point Display Text Panel will start up in the RUN Mode. To
access the SETUP Mode, follow these steps:
1.
Press
the
UP Arrow
Pushbutton and hold while simultaneously pressing
the
DOWN Arrow
Pushbutton to enter the SETUP Mode.
2. At any time you may press the Escape (
esc
) button to go back to RUN
Mode. You will be taken back to the start of the Local Message menu
(cursor is placed at root level when you return from setup).
Adjust Display Contrast
You may only adjust the Display Contrast when in Setup Mode. To adjust the
display contrast use the UP and DOWN arrows to increase or decrease the
contrast.
Internal Software and Hardware Revisions
While in
SETUP
Mode the Panel Hardware Revision, Driver Revision, Boot
Revision, and Exec (Firmware) Revision numbers will display on the panel.
Preparing for Confi guration
If you prepare and plan ahead of time, your use of the EZSeries Set Point Display
Text Panel Programming software will be successful. Below are a few important
steps to take to prepare to program your application.
•
Prepare your personal computer and ensure proper installation of
the EZSeries Set Point Display Text Panel Programming Software
•
Know your operator interface requirements. Determine the type of
EZSeries Set Point Display Text Panel and the number of EZSeries
Set Point Display Text Panels
required by your application
•
Know your PLC type and available resources, such as, programming
tools,
CPU capabilities, user memory, etc.
•
Verify type of communications port, as well as protocol used.
Determine the CPU link(s) available for connecting an EZSeries Set
Point Display Text
Panel
EZSeries Set Point Display Text Panel Setup
SETUP MODE
DRV. REV.:
Содержание EZ-220
Страница 27: ...23 EZ TEXT M E Text Panel Hardware Manual Connections and Wiring EZSeries Text Panel Application...
Страница 46: ...42 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Страница 65: ...61 EZ TEXT M E Text Panel Hardware Manual...
Страница 80: ...76 EZ TEXT M E Text Panel Hardware Manual...
Страница 81: ...77 EZ TEXT M E Text Panel Hardware Manual...
Страница 88: ...84 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Страница 100: ...96 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Страница 114: ...B 8 Text Panel Hardware Manual Omron C200 C500 RS 232 P N EZP OMRON CBL Siemens S7 MPI Adaptor P N EZP S7MPI CBL...
Страница 118: ...B 12 Text Panel Hardware Manual Idec MicroSMART PLC RS232 8 pin Mini DIN Male P N EZP IDECS CBL...
Страница 120: ...B 14 Text Panel Hardware Manual This page intentionally left blank...
Страница 150: ...I 8 EZ TEXT M Text Panel Hardware Manual This page intentionally left blank...