Power Over Ethernet
ExtremeWare XOS 11.1 Concepts Guide
114
The command provides status for the following areas:
●
Configured inline power status—The status of the inline power for the switch: enabled or disabled.
●
System power surplus—The surplus amount of power on the system, in watts, available for
budgeting.
●
Redundant power surplus—The amount of power on the system, in watts, available for budgeting if
one power supply is lost.
●
System power usage threshold—The configured power usage threshold for each slot, shown as a
percentage of budgeted power. Once this threshold has been passed on any slot, the system sends an
SNMP event and logs a message.
●
Disconnect precedence—The method of denying power to PDs if the budgeted power on any slot is
exceeded.
●
Legacy mode—The status of the legacy mode, which allows detection of non-standard PDs.
The output indicates the following inline power status information for each slot:
●
Inline power status—The status of inline power. The status conditions are:
■
Enabled
■
Disabled
●
Firmware status—The operational status of the slot. The status conditions are:
■
Operational
■
Not operational
■
Disabled
■
Subsystem failure
■
Card not present
■
Slot disabled
●
Budgeted power—The amount of inline power, in watts, that is reserved and available to the slot.
●
Measured power—The amount of power, in watts, that is currently being used by the slot.
Following is sample output from this command:
Inline Power System Information
Configured : Enabled
System Power Surplus : 1500 Watts available for budgeting
Redundant Power Surplus : 465 Watts available for budgeting to maintain N+1
Power Usage Threshold : 70 percent (per slot)
Disconnect Precedence : lowest-priority
Legacy Mode : Disabled
Budgeted Measured
Slot Inline-Power Firmware Status Power (Watts) Power (Watts)
3 Enabled Operational 50 W 9 W
4 Enabled Card Not Present ( 50 W) n/a
7 Enabled Operational 50 W 0 W
Note: A budget value in parentheses is not allocated from the system power
budget because the card is not present, or the slot is disabled.
Содержание ExtremeWare XOS 11.1
Страница 16: ...Contents ExtremeWare XOS 11 1 Concepts Guide 16...
Страница 20: ...Preface ExtremeWare XOS 11 1 Concepts Guide 20...
Страница 21: ...1 Using ExtremeWare XOS...
Страница 22: ......
Страница 78: ...Managing the ExtremeWare XOS Software ExtremeWare XOS 11 1 Concepts Guide 78...
Страница 168: ...Virtual LANs ExtremeWare XOS 11 1 Concepts Guide 168...
Страница 200: ...Policies and ACLs ExtremeWare XOS 11 1 Concepts Guide 200...
Страница 252: ...Security ExtremeWare XOS 11 1 Concepts Guide 252...
Страница 265: ...2 Using Switching and Routing Protocols...
Страница 266: ......
Страница 294: ...Ethernet Automatic Protection Switching ExtremeWare XOS 11 1 Concepts Guide 294...
Страница 354: ...Extreme Standby Router Protocol ExtremeWare XOS 11 1 Concepts Guide 354...
Страница 416: ...IP Multicast Routing ExtremeWare XOS 11 1 Concepts Guide 416...
Страница 417: ...3 Appendixes...
Страница 418: ......
Страница 432: ...Software Upgrade and Boot Options ExtremeWare XOS 11 1 Concepts Guide 432...