Configuring Slots and Ports on a Switch
ExtremeWare XOS 11.1 Concepts Guide
100
.
5:106 VR-Default E R ON AUTO AUTO UTP
5:107 VR-Default E R ON AUTO AUTO UTP
5:108 VR-Default E R ON AUTO AUTO UTP
================================================================================
Link Status: A-Active R-Ready
Port State: D-Disabled E-Enabled
NOTE
On 10 Gbps ports, the Media Primary column displays NONE when no module is installed, and SR, LR, or ER
depending on the module installed when there is one present.
The following sample command displays the port configuration statistics for slot 2, port 2:
show ports 2:2 configuration
Following is sample output from this command:
Port Configuration
Port Virtual Port Link Auto Speed Duplex Flow Load Media
router State State Neg Cfg Actual Cfg Actual Cntrl Master Primary
================================================================================
2:2 VR-Default E R ON AUTO AUTO UTP
================================================================================
Link Status: A-Active R-Ready
Port State: D-Disabled E-Enabled
The
show ports information
command shows you either summary information on all the ports, or
more detailed information on specific ports. The output from the command differs very slightly
depending on the platform you are using.
The following sample output is from the
show ports information
command and displays the port
configuration for all ports:
QB_Mariner.4 > show port 3:1 info
Port Diag Flags Link Link Num Num Num Jumbo QOS Load
State UPS STP VLAN Proto Size profile Master
================================================================================
3:1 P Em------e-- ready 0 0 1 1 9216
================================================================================
Flags : a - Load Sharing Algorithm address-based, D - Port Disabled,
e - Extreme Discovery Protocol Enabled, E - Port Enabled,
f - Flooding Enabled, g - Egress TOS Enabled, j - Jumbo Frame Enabled,
l - Load Sharing Enabled, m - MACLearning Enabled,
n - Ingress TOS Enabled, o - Dot1p Replacement Enabled,
P - Software redundant port(Primary),
q - Background QOS Monitoring Enabled, R - Software redundant port(Redunda
nt),
s - diffserv Replacement Enabled, r - Load Sharing Algorithm round-robin
v - Vman Enabled
Содержание ExtremeWare XOS 11.1
Страница 16: ...Contents ExtremeWare XOS 11 1 Concepts Guide 16...
Страница 20: ...Preface ExtremeWare XOS 11 1 Concepts Guide 20...
Страница 21: ...1 Using ExtremeWare XOS...
Страница 22: ......
Страница 78: ...Managing the ExtremeWare XOS Software ExtremeWare XOS 11 1 Concepts Guide 78...
Страница 168: ...Virtual LANs ExtremeWare XOS 11 1 Concepts Guide 168...
Страница 200: ...Policies and ACLs ExtremeWare XOS 11 1 Concepts Guide 200...
Страница 252: ...Security ExtremeWare XOS 11 1 Concepts Guide 252...
Страница 265: ...2 Using Switching and Routing Protocols...
Страница 266: ......
Страница 294: ...Ethernet Automatic Protection Switching ExtremeWare XOS 11 1 Concepts Guide 294...
Страница 354: ...Extreme Standby Router Protocol ExtremeWare XOS 11 1 Concepts Guide 354...
Страница 416: ...IP Multicast Routing ExtremeWare XOS 11 1 Concepts Guide 416...
Страница 417: ...3 Appendixes...
Страница 418: ......
Страница 432: ...Software Upgrade and Boot Options ExtremeWare XOS 11 1 Concepts Guide 432...