BERT Tabs
SONET/SDH Application
337
Pattern TX
Error Injection
Allows selection and configuration of a manual or automated pattern error
that will be generated.
Type
:
The only available type of pattern error is
Bit Error
.
Amount
: Select the amount of error to be generated. Choices are
1
through
50
. The default setting is
1
.
Send
button: Press
Send
to manually generate the pattern error according
to the pattern error type and the amount.
Rate
:
Press the
Rate
field to select the rate for the selected pattern error.
The rate must be within the minimum and maximum values specified.
Continuous
:
Generates the selected error to its theoretical maximum
when the
Continuous
check box is selected while the
On/Off
button is
enabled (On). The
Continuous
check box is cleared by default.
On/Off
button: The On/Off button is used to activate/deactivate the
selected automated pattern error at the rate specified or at its theoretical
maximum rate when the
Continuous
check box is selected. This setting is
disabled (Off) by default.
Note:
Manual and Automated error injection can run simultaneously.