SDH Tabs
254
FTB-8100 Series Transport Blazer
Regenerator Section TX (SDH)
J0 Trace
³
Format
:
Displays the J0 value in
16
or
64 bytes
format. The default
setting is
16 bytes
.
³
Message
:
Enter the J0 trace value in 16 or 64 bytes format as selected.
The default message is
EXFO SONET/SDH
for 16 bytes and
EXFO
SONET/SDH Analyzer Section/RS trace test message
for 64 bytes.
³
Enable Trace
:
Generates the defined J0 Trace message when the
Enable Trace
check box is selected. The
Enable Trace
check box has
to be selected to give access to the trace format and message. When
the
Enable Trace
check box is cleared, the J0 1-byte format is used
and can be configured from the
Regenerator Section OH TX (SDH)
on
page 257.
Note:
16-bytes selection allows typing up to 15 bytes (a CRC-7 byte will be added
in front for a total of 16 bytes). 64-bytes selection allows typing up to
62-bytes (<C
R
> and <L
F
> bytes will be added at the end for a total of
64-bytes).