Creating and Starting a Test Case
SONET/SDH Application
71
Typical Test Cases
Creating an Optical SONET/SDH Test Case
(FTB-8115/20/30)
The following procedure describes a normal optical SONET/SDH the test
case on the FTB-8115/20/30 modules.
To create an Optical SONET/SDH Test on an FTB-8115/20/30
module:
1.
Test configuration:
1a.
Select the source
Clock
Mode
that will be used
for the test. Refer to
Clock Configuration
on
page 101 for more
information.
1b.
Select
Normal
as the
Test Mode
. Refer to Test
Configuration
on page 98
for more information.
1c.
Select the
Coupled
check box to set the same settings for both
the TX and RX signals or clear the
Coupled
check box to
configure the TX and RX signal individually (decoupled).
1d.
Select the
Through
check box to loop the RX signal to the TX port.
The
Clock Mode
is automatically set to
Recovered
when the
Through
check box is selected.
2.
Press the
Port
node.
2a.
Press
More
to see all
available interfaces and
press the desired
interface:
OC-3
,
OC-12
,
OC-48
,
OC-192
,
STM-1
,
STM-4
,
STM-16
,
STM-64
. Choices depend on the rates available on the
FTB-8115/20/30 module.
Содержание FTB-8100 Series
Страница 1: ...User Guide FTB 8100 Series for FTB 200 SONET SDH Application...
Страница 18: ......
Страница 22: ......
Страница 24: ......
Страница 94: ......
Страница 108: ......
Страница 178: ......
Страница 224: ......
Страница 260: ......
Страница 312: ......
Страница 352: ......
Страница 382: ......
Страница 412: ......
Страница 490: ......
Страница 500: ......