SONET Tabs
SONET/SDH Application
205
LOP TX (SONET)
Alarm Generation
Allows
Continuous
alarm generation method.
³
Type
:
The following alarms are available:
AIS-V
(Alarm Indication Signal - VT): Generates an all-ones pattern for
the V1 and V2 bytes of the VT path and payload.
RDI-V
(Remote Defect indication - VT):
Generates “1” for the bit 8 of
the V5 byte and a “00” pattern for bits 6 and 7 of the Z7 byte.
ERDI-VSD
(Enhanced RDI - VT Server Defect): Generates a “101”
pattern for bits 5, 6, and 7 of the Z7 byte, and “1” for bit 8 of the V5 byte.
ERDI-VCD
(Enhanced RDI - VT Connectivity Defect): Generates a “110”
pattern for bits 5, 6, and 7 of the Z7 byte, and “1” for bit 8 of the V5 byte.
ERDI-VPD
(Enhanced RDI - VT Payload Defect): Generates a “010”
pattern for bits 5, 6, and 7 of the Z7 byte, and “0” for bit 8 of the V5 byte.
RFI-V
(Remote Failure Indication - VT): Generates “1” for the bit 4 of
the V5 byte.
LOP-V
(Loss of Pointer - VT): Generates a non-valid pointer.
UNEQ-V
(Unequipped - VT): Generates samples of unequipped VT
signal label (bits 5 through 7 of V5 byte are set to “000”).
³
On/Off
button: The On/Off button is used to activate/deactivate the
selected alarm. This setting is disabled (Off) by default.
Содержание FTB-8100 Series
Страница 1: ...User Guide FTB 8100 Series for FTB 200 SONET SDH Application...
Страница 18: ......
Страница 22: ......
Страница 24: ......
Страница 94: ......
Страница 108: ......
Страница 178: ......
Страница 224: ......
Страница 260: ......
Страница 312: ......
Страница 352: ......
Страница 382: ......
Страница 412: ......
Страница 490: ......
Страница 500: ......