Creating and Starting a Test Case
56
FTB-8100 Series Transport Blazer
Typical Test Cases
Creating an Electrical DSn/PDH Test Case in Normal
Mode
The following procedures describe the creation of an electrical DSn/PDH
test case in
Normal
mode.
To create an Electrical DSn/PDH Test in Normal mode:
1.
Test configuration:
1a.
Select the source
Clock
Mode
that will be used
for the test. Refer to
Clock Configuration
on
page 101 for more
information.
1b.
Select
Normal
as the
Test Mode
. Refer to Test
for more information.
1c.
Select the
Coupled
check box to set the same settings for both
the TX and RX signals or clear the
Coupled
check box to
configure the TX and RX signal individually (decoupled).
1d.
Select the
Through
check box to loop the RX signal to the TX port.
The
Clock Mode
is automatically set to
Recovered
when the
Through
check box is selected.