SDH Tabs
SONET/SDH Application
277
HOP RX (SDH)
Alarm Analysis
³
AU-AIS
(Administrative Unit - Alarm Indication Signal): The AU-AIS
alarm is declared when the H1 and H2 bytes contain an all-ones
pattern in three consecutive frames.
³
AU-LOP
(Administrative Unit - Loss Of Pointer): The LOP alarm
indicates that a valid pointer is not found in N consecutive frames
(where 8
≤
N
≤
10), or that N consecutive NDFs (“1001” pattern) are
detected (non-concatenated payloads).
³
H4-LOM
(H4 - Loss Of Multiframe): For TU structured optical frames,
the H4-LOM alarm indicates that the system loss track of the H4 byte
multiframe indicator sequence.
³
HP-RDI
(High Order Path - Remote Defect Indication): The HP-RDI
alarm is declared when bits 5, 6 and 7 of the G1 byte contain the “100”
or “111” pattern in five consecutive frames.
³
HP-TIM
(High Order Path - Trace Identifier Mismatch): The HP-TIM
defect indicates that the received J1 Trace doesn’t match the expected
message value. The HP-TIM alarm result is only available when
Enable
HP-TIM
check box from J1 Trace section has been selected.
³
HP-PLM
(High Order Path - Payload Label Mismatch): The HP-PLM is
declared upon receipt of five consecutive frames with mismatched VC
signal labels (C2 byte).
³
HP-UNEQ
(High Order Path - Unequipped): HP-UNEQ is declared
when the C2 bytes contain “00 H” in five consecutive frames.
³
ERDI-SD
(Enhanced RDI - Server Defect): The ERDI-SD alarm is
declared when bits 5, 6 and 7 of the G1 byte contain the “101” pattern
in five consecutive frames.
Содержание FTB-8100 Series
Страница 1: ...User Guide FTB 8100 Series for FTB 200 SONET SDH Application...
Страница 18: ......
Страница 22: ......
Страница 24: ......
Страница 94: ......
Страница 108: ......
Страница 178: ......
Страница 224: ......
Страница 260: ......
Страница 312: ......
Страница 352: ......
Страница 382: ......
Страница 412: ......
Страница 490: ......
Страница 500: ......