Page 6
C Copyright 2005 Exel Orbital
All Rights Reserved
1.
2.
3.
4.
5.
6.
Power Supply Hook Up
Start by inserting the A/C line plug into
power ranging from 85 to 265 volts and
from 47 to 63 hertz single phase.
Connect the power, ground, motor, gas
and remote (if applicable) of the welding
head to the power supply.
Chapter 1
Start Up
Notes:
1. The EPS-1000 does not require a
dedicated circuit.
2. Power Input: 85 to 265 volts and
47 to 63 hertz.
3. Purge Input: 15 to 80 psi or 100
to 530 Kpa.
Above is a view of the back of the EPS-
2000 Power Supply with all necessary
connectors visible.
Connect the Argon or mixed gas purge
inlet from the source to the power sup-
ply.