Page 26
C Copyright 2005 Exel Orbital
All Rights Reserved
1.
2.
3.
4.
5.
6.
Utility
Push anywhere on the MAIN Menu.
Press UTILITY from the LIBRARY Menu.
UNITS: - ENGLISH or METRIC may be selected
here when toggling from one to the next the units
are changed throughout the program and con-
versions are automatically made.
DEFAULT START CURRENT: - The default cur-
rent used to initiate the arc start of the weld is 40
amps. This is the instantaneous current to es-
tablish the arc from the electrode. This value
can be adjusted from 25 to 40 Amps.
POWER ADJUST: - This value establishes the
adjustment the operator is given during welding.
This value is given as a % of the programmed
current. The operator has the ability to adjust
power in 1% increments up or down to the pro-
grammed limit in POWER ADJUST.
DO YOU WANT TO SAVE ALL DATA LOG?
Answer YES or NO to this. If you answer NO
weld reports will not be saved and can only be
printed immediately following the weld, subse-
quent welds will overwrite the report. If you an-
swer YES weld reports will be saved to the CF
Card in Microsoft Excel format in the LOG
Folder. Again the weld report may be printed
after the weld.