Design and function
Special parameters (advanced settings)
92
099-005403-EW501
18.08.2016
Display
Setting/selection
Enable special jobs SP1 to SP3
0 = ------- no enabling (Ex works)
1 = ------- enabling of Sp1-3
Correction operation, threshold value setting
0 = ------- correction operation switched off (Ex works)
1 = ------- correction operation on
"Main program (PA)" flashing
Program changeover with standard torch
0 = ------- no program changeover (Ex works)
1 = ------- special latched
2 = ------- specific latched special (n cycle active)
Lat. and sp. lat. tapping start
0 = ------- no latched tapping start (Ex works)
1 = ------- latched tapping start possible
One or two-wire feed operation
0 = ------- single operation (Ex works)
1 = ------- dual operation, this unit is the "master"
2 = ------- dual operation, this unit is the "slave"
Special latched tapping time
0 = tapping function switched off
1 = 300ms (Ex works)
2 = 600ms
JOB list changeover
0 = ------- task-oriented JOB list
1 = ------- actual JOB list (Ex works)
2 = ------- actual JOB list, JOB changeover activated via accessories
Lower limit remote JOB changeover
Lowest JOB that can be selected using PowerControl 2 torches.
Lower limit: 129 (Ex works)
Upper limit remote JOB changeover
JOB range of the POWERCONTROL2 torch
Upper limit: 169 (Ex works)
HOLD function
0 = ------- HOLD values are not displayed
1 = ------- HOLD values are displayed (Ex works)
Block JOB mode
0 = ------- Block JOB mode not enabled (Ex works)
1 = ------- Block JOB mode enabled
Program selection with standard torch trigger
0 = ------- no program selection (Ex works)
1 = ------- program selection possible
Switching the operating mode and welding type using the wire feed control
0 = ------- Switching the operating mode and welding type using the wire feed control and
program 0 (factory setting).
1 = ------- Switching the operating mode and welding type using the wire feed control and
programs 0-15.
Mean value display for superPuls
0 = ------- Function switched off.
1 = ------- Function switched on (ex factory).