Design and function
Machine configuration menu
099-005403-EW501
18.08.2016
103
Predefined absolute value for relative programs (P21)
Start program (P
START
), down-slope program (P
B
) and end program (P
END
) can be set relative to the main
program (P
A
) or in an absolute manner, as desired.
Function active (P21 = 1)
• Absolute parameter setting
Function inactive (P21 = 0)
• Relative parameter setting (ex factory)
Electronic gas flow control, type (P22)
Active only in machines with integrated gas flow control (option ex works).
Adjustment may only be carried out by authorised service personnel (basic setting = 1).
Program settings for relative programs (P23)
The start, down-slope and end program relative programs can be set individually or combined for the P0-
P15 operating points. When choosing the combined setting, in contrast to the individual setting, the
parameter values are saved in the JOB With the individual setting, the parameter values are identical for
all JOBs (except for special JOBs SP1,SP2 and SP3).
Correction or nominal voltage display (P24)
When setting the arc correction using the right-hand rotary knob the display will either show the correction
v- 9.9 V (ex works) or the absolute nominal voltage.
5.11 Machine configuration menu
5.11.1 Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off the machine at the main switch.
• Press and hold the "welding parameters" or "choke effect" (drive 4X LP) push-button and
switch the machine on again at the same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "welding parameter setting" rotary knob.
• Set or change parameters by turning the "arc length correction/select welding program" rotary
knob.
EXIT (Exit the menu)
• Press the "parameter selection right" push-button (switch machine off and on again).