Design and function
Special parameters (advanced settings)
099-005403-EW501
18.08.2016
91
5.10.1 Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off machine at the main switch.
• Press and hold the "left parameter selection" button and switch the machine on again at the
same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "welding parameter setting" rotary dial.
• Set or change the parameters by turning the "arc length correction/select welding program"
rotary dial.
EXIT (Exit the menu)
• Press the "right parameter selection" button (switch machine off and on again).
ENTER
B
A
A
l
0
l
0
+
EXIT
B
NAVIGATION
A
B
A
Figure 5-73
Display
Setting/selection
Ramp time for wire inching
0 = -------- normal inching (10s ramp time)
1 = -------- fast inching (3s ramp time) (Ex works)
Block program "0"
0 = -------- P0 enabled (Ex works)
1 = -------- P0 blocked
Display mode for Up/Down welding torch with one-digit 7-segment display (two
keys)
0 = -------- normal display (ex works) program number/welding power (0
–9)
1 = -------- display toggles between program number/welding type
Program limitation
Programs 1 to max. 15
Ex works: 15
Special cycle in the special latched and non-latched operating modes
0 = -------- normal (previous) non-latched/latched (Ex works)
1 = -------- WF3 cycle for non-latched/latched