Design and function
MIG/MAG welding
66
099-005403-EW501
18.08.2016
5.3.11.2 MIG/MAG
overview of parameters
P
START
, P
B
, and P
END
are set as relative programs ex faxtory. They relate to percentages of the wire
feed value of the main program P
A
. These programs can also be set in an absolute manner, if
desired (see Setting of special parameter P21).
Figure 5-46
Basic Parameters
Item
Meaning / Explanation
Setting Range
1
1
Gas pre-flow time
0.0s to 20.0s
2
2
P
START
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
3
3
Duration
0.0s to 20.0s
4
4
Slope duration from P
START
to P
A
0.0s to 20.0s
5
5
P
A
Wire speed, absolute
0.1 m/min to 40 m/min
6
7
Duration (spot time and superpulse)
0.01s to 20.0s
7
8
P
B
Wire speed, relative
Arc length correction, relative
1% to 200%
-9.9V to +9.9V
8
9
Duration
0.01s to 20.0s
9
1
0
Slope duration from P
A
to P
END
0.0s to 20s
10 1
1
P
END
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
11 1
2
Duration (superpulse)
0.0s to 20s
12 1
3
Gas post-flow time
0.0s to 20s
13 1
4
superPuls
On / Off