Rectifying faults
General operating problems
114
099-005403-EW501
18.08.2016
7.3.2
Resetting all JOBs
JOBs 1
–128 and 170–256 will be reset.
Custom JOBs 129
–169 are maintained.
EXIT
3s
ENTER
3s
ENTER
3s
Figure 7-2
Display
Setting/selection
RESET to factory settings
The RESET will be done after pressing the button.
The menu will be ended when no changes are done after 3 sec.
7.4
General operating problems
7.4.1
Automation interface
WARNING
No function of the external interrupt equipment (emergency stop switch)!
If the emergency stop circuit has been set up using an external interrupt equipment
connected to the interface for automated welding, the machine must be configured for
this setup. If this is not observed, the power source will ignore the external interrupt
equipment and will not shut down!
• Remove jumper 1 on the T320/1, M320/1 or M321 PCB!