Operating the machine control
Setup mode
38
099-00L104-EW501
17.01.2022
Item Symbol Description
0
4
Advanced settings
Display and setting of advanced process parameters
5
WPQR welding data assistant
Menu item / parameter
Value
Comment
Automatic
No
Yes
The welding monitoring window opens auto-
matically from the main screen after a welding
start. A rotary knob actuation automatically
switches back to the main window.
Errors and warnings
Off
Warnings
Exceeding a tolerance limit for the duration of
the tolerance response time triggers warning
12.
Error
Exceeding a tolerance limit for the duration of
the tolerance response time triggers error 61.
Please note: Error leads to immediate stop of
the ongoing welding!
Voltage tolerance
0-100 %
Current tolerance
0-100 %
Tolerance response time
0.00-20.0 s
For voltage and current tolerance
Wire feeder tolerance
0-100 %
Maximum permissible motor current
0.0-5.0 A
Tolerance response time
0.00-20.0 s
For WF tolerance and motor current