Operating the machine control
Setup mode
099-00L104-EW501
17.01.2022
39
5.7.3 Process parameters
5.7.3.1 Ignition parameters
Menu item/parameter
Value
Comment
I-ign:
1–1000 A
WF-ign:
0.0–100.0%
WF-ign 1:
0.0-
20.0 m/min.
U-ign:
0.0–38.2 V
T-ign:
0.1–20.0 ms
I-sense:
0–500 A
WF-sense:
0.0–
20.0 m/min.
MI
OFF
ON
5.7.3.2 Wire retraction ignition
Menu item/parameter
Value
Comment
Wire retraction ignition:
OFF
Lift arc (PP)
Lift arc
I-ign 1:
0–250 A
I-ign 2:
0–500 A
T-ign 2:
0.0–100.0 ms
TV-pro:
0–200 ms
WF-back:
5–150
TV-back:
0–250 A
5.7.3.3 WF setting range
Menu item/parameter
Value
Comment
WF-min.:
0.0–
40.0 m/min.
WF-max.:
0.0–
40.0 m/min.
5.7.3.4 Process signal handling
Menu item/parameter
Value
Comment
TZ-ign:
0.00–5.00 s
TZ-libo:
0.00–5.00 s
TZ-set:
0–500 ms
TZ-reset:
0–500 ms