Operating the machine control
Setup mode
099-00L104-EW501
17.01.2022
37
Item Symbol Description
0
3
Push-button, gas test/purge hose package
• ----------- Gas test:
Shielding gas (symbol flashes slowly) will flow for approximately 20 seconds
after pressing the push-button once. Press the button again to cancel the pro-
cess early.
• ----------- Purge hose package:
Press push-button for about 5 sec: Shielding gas flows permanently (mac 300
s) until the Gas test push-button is pressed again (shielding gas flashes fast).
All functions run without current (set-up phase). This provides a high degree of safety for the welder,
since the arc cannot be inadvertently ignited. The following parameters can be monitored during the wire
configuration:
Menu item/parameter
Value
Comment
WF nominal value
0.0 m/min
only if the control is integrated in the wire fee-
der
WF actual value
0.0 m/min
Motor current
0.0 A
Gas nominal value
0.0 l/min
GFE option/variant (electronic
gas volume control) required
Gas flow
0.0 l/min
5.7.1 WPQR welding data assistant
The cooling-down time from 800°C to 500°C essential for the welding result (known also as t8/5 time) can
be calculated using the input data in the WPQR welding data assistant. Prerequisite is the prior determi-
nation of the heat input. Upon input of the values, the valid t8/5 time is displayed with a black background.
Menu item/parameter
Value
Comment
Weld length:
1.0-999.9 cm
Welding speed:
1.0-
999.9 cm/min.
Thermal efficiency:
10-100%
Heat input:
kJ/mm
Preheating temperature:
0-499 °C
Material thickness:
1.0-999.9 mm
Weld seam factor:
0.01-1.5
Transition thickness:
mm
t8/5-time:
s
5.7.2 Welding monitoring
Figure 5-15
Item Symbol Description
0
1
Current tolerance
2
WF tolerance
3
Voltage tolerance