5.4.4 System settings
In this area the user can configure advanced system settings.
5.4.4.1 Date
Menu item/parameter
Value
Comment
Year:
2014
Month:
10
Day:
28
Date format:
DD.MM.YYYY
YYYY.MM.DD
5.4.4.2 Time
Menu item/parameter
Value
Comment
Hour:
0–24
Minute:
0–59
Time zone (UTC +/-):
-12h to +14h
Summer time:
Yes
No
Time format:
24 h
12 h AM/PM
5.4.4.3 Water block
Permanently switching off the water block may damage the welding torch.
Menu item / parameter
Value
Comment
Cooling unit postflow time [min.]:
1-60 min
Cooling unit control:
Automatic
Permanently
ON
Permanently
OFF
Temperature error limit
50-80 °C
Flow monitoring
On
Off
Flow error limit
0.5-2.0 l/min
Reset to factory setting
No
Yes
Resets the water block parameters to factory
settings.
5.4.4.4 Control
Menu item / parameter
Value
Comment
Operation without wire feeder is pos-
sible
(This parameter controls the system be-
haviour depending on the connected
wire feeder)
No (factory
setting)
The wire feeder (WF) can be changed during
operation.
Operation without a connected wire feeder is
not possible.
Yes
The welding system can be operated without a
wire feeder connected.