Operating the machine control
Welding task administration (Menu)
34
099-00L104-EW501
17.01.2022
5.6.1 JOB selection (material/wire/gas)
The welding task (JOB) can be set in two ways:
a) Enter the relevant JOB number. Each welding task has a unique JOB number (for predefined
JOBs
> see 9.2 chapter
, see the JOB list in the annex or the sticker on the machine).
b) Enter the basic welding parameters: welding procedure, material type, wire diameter and shielding gas
type.
5.6.2 JOB manager
5.6.2.1 Copy JOB to number
Copy JOB to a number of the definable range (129–169).
5.6.2.2 Reset current JOB
Reset all parameters of the selected JOB to the factory setting
5.6.2.3 Reset all JOBs
Reset all JOBs to the factory setting, except JOBs in the definable range (129–169)
> see 8.4 chapter
.
5.6.3 Program sequence
The setting range for the parameter values are summarised in the parameter overview
section
> see 9.1 chapter
.
In the program sequence, you can select welding parameters and set their values. The number of para-
meters shown depends on the selected operating mode.
In addition, the user can access advanced settings and the setup mode.
Figure 5-12
Item Symbol Description
0
1
▲
Parameter position
Displays the currently selected welding parameters in the functional sequence
2
Advanced settings
Display and setting of advanced process parameters
3
Setup mode
> see 5.7 chapter
4
Operating mode setting