IN1 XX% Loop
Warning
A change to this parameter requires an application reboot (
ALT+Q
from the
operational windows) to be taken into account.
Description
This parameter contains two types of information on the
specified recorder:
Recording Capacity: XX%
percentage of the disk space
allocated to each channel.
Loop / No Loop:
indicates whether the Loop Recording
parameter is enabled or not.
Values
The following values are possible:
•
Recording Capacity:
The value is defined by the user.
The total of all values must not exceed 100%.
By default, the recording capacity is evenly distributed
among all recorders.
Example:
In a 2 REC 2 PLAY configuration, the recording
capacity will be 50% for each recorder by default.
•
Loop / No Loop:
•
The value directly depends on the Loop Recording setting:
◦
If the Loop Recoding is enabled, the value will be
'Loop'.
◦
If the Loop Recording is disabled, the value will be 'No
Loop'.
3.4.3.
Audio
Audio and Audio Monitoring Settings
User Interface
The Audio settings allow users to specify, among others, the physical configuration for
audio connectors, and the number of audio tracks.
The Audio Monitoring settings allow users to specify which audio signals are monitored.
These fields are available in the following interfaces:
•
in the Multicam Configuration window, Channels tab, in the advanced display mode:
◦
on page 2 on the server-based application
◦
on the web-based interface
•
in the Technical menu of the Remote Control Panel (T2.X).
CONFIGURATION MANUAL XSnano Server 12.02
3. Multicam Configuration
95
Содержание XSnano
Страница 1: ...CONFIGURATION MANUAL Version 12 02 April 2014 ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 57: ...CONFIGURATION MANUAL XSnano Server 12 02 3 Multicam Configuration 47 ...
Страница 70: ...Rear panels before 2013 60 3 Multicam Configuration EVS Broadcast Equipment SA Issue 12 02 C April 2014 ...
Страница 194: ......
Страница 197: ......