Timecode Status
Introduction
The Timecode Status section displays the settings for managing and monitoring the
timecode jump tables. Records are created in these tables when a break, or jump, in the
timecodes occurs in the recorded material. The records in the timecode jump tables are
then used to search for and manipulate the video material on the XSnano server.
There are two timecode jump tables:
•
Timecode jump table for the LTC timecodes
•
Timecode jump table for the timecodes specified by the user in the Multicam
Configuration module,
Channels
tab,
Timecode Settings
area,
User
field.
See section "Timecode Settings" on page 112 for more information on this setting.
LTC Timecode
LTC
Description
Default
Values
LTC jumps
Number of timecode jumps calculated in the LTC timecode
jump table for the given recorder since the last start of the
server.
1
LTC threshold
Number of continuous timecodes to be received, after a
break in LTC timecodes in the recorded material, in order to
create a new record in the LTC timecode jump table.
50
Peak alerts
Number of peak alerts generated for the recorder since the
last start of the server.
A peak alert is generated each time the peak limit specified
in the Peak Limit field is reached.
In this case, this field is automatically incremented by one.
0
Peak limits
(sec)
Period of time (in seconds) of continuous timecodes after
which a break in timecodes in the recorded material will
generate a peak alert. When a peak alert is generated, the
value in Peak Alerts field is incremented by one.
10
Frequency
alert
Number of frequency alerts generated for the recorder since
the last start of the server.
A frequency alert is generated when X timecode jumps have
been detected in Y seconds.
The X value is defined in the Frequency Number field. The Y
value is defined in the Frequency Time field.
In this case, this field is automatically incremented by one.
0
Frequency
number
Number of timecode jumps detected for the recorder after
which a frequency alert can be generated.
10
Frequency
time
Period of time (in seconds) after which a frequency alert can
be generated.
50
176
4. Monitoring
EVS Broadcast Equipment SA
Issue 12.02.C - April 2014
Содержание XSnano
Страница 1: ...CONFIGURATION MANUAL Version 12 02 April 2014 ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 57: ...CONFIGURATION MANUAL XSnano Server 12 02 3 Multicam Configuration 47 ...
Страница 70: ...Rear panels before 2013 60 3 Multicam Configuration EVS Broadcast Equipment SA Issue 12 02 C April 2014 ...
Страница 194: ......
Страница 197: ......