INSTALLATION INSTRUCTIONS
A f f i n i t y 3 0 G e
Evo, Inc. | 8140 SW Nimbus Ave., Bldg 5 | Beaverton, Oregon 97008 USA
Phone 503.626.1802 | Fax 503.213.5869 | www.evoamerica.com | [email protected]
9
36” clearance to ceiling from cook surface
CLEARANCE DIMENSIONS
Read the instructions carefully in this booklet to install the
Evo Affi nity 30Ge Cooktop to a metal, stone or wood countertop surface.
Cabinet layout and construction may vary.
12” clearance to sidewall
from cook surface
12” clearance to backwall
from cook surface
Minimum 3” clearance required under unit
venting to 22 sq/in of combustible air.
Do not install above any equipment, table or shelving where
air temperature is greater than ambient air temperature.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION FROM CHASSIS
Combustibles
Non-combustibles
Back
3/8”
0”
Sides
3/8”
0”
Bottom
3”
3”
CLEARANCE TO COMBUSTIBLE SURFACE FROM COOKING SURFACE
Top
36”
Sides
12”