INSTALLATION INSTRUCTIONS
A f f i n i t y 3 0 G e
Evo, Inc. | 8140 SW Nimbus Ave., Bldg 5 | Beaverton, Oregon 97008 USA
Phone 503.626.1802 | Fax 503.213.5869 | www.evoamerica.com | [email protected]
17
STEP 7:
Before picking up cook surface, rotate each of the two front slotted captive fastener
screws counter-clockwise and back them out fully. Then position the cook surface at the rear
of the burner chassis by placing the cook surface in the area of the drip pan, separated by a
towel or cardboard to prevent damage to the drip pan.
CONNECTING COOK SURFACE - ELECTRICAL CONNECTIONS 1 of 2
Using a Phillips #3 Flat
Screwdriver, back out each of the
two front captive fasteners on the
chassis skirt counter-clockwise
until they stop. Do not twist
fastener beyond the stop.
SIDE VIEW OF FRONT
CAPTIVE FASTENERS
TC (Thermal Couple Temperature Detector)
Used To Electrically Monitor Cook Surface Temperatures At Inner And Outer Zones. The Affi nity 30Ge
uses K-Value TC’s.
The numbers show TC threaded stud locations for attaching TC wires. Each TC stud location has a
corresponding numbered TC connection wire located at a respective location on the heat shield under
the burners. When cook surface is lowered to its fi nal location, the TC studs and wires are vertically
aligned.
The Inner Zone (Inner Burner) has one TC at #1 position. The Outer Zone (Outer Burner) has three
TC’s at positions #2, #3, and #4. The Outer TC’s average three locations for consistent temperature
delivery.
1
2
3
4
Inner Zone
Outer Zone
Outer Zone
Outer Zone
1
2
4
3
Place suitable
protection on
drip pan (towel or
cardboard). Place
cook surface
vertically with
Bullet Fastener
facing downward.
IT IS HIGHLY RECOMMENDED THAT TWO INSTALLERS BE PRESENT TO
CONNECT THE TC’S AND INSTALL THE COOK SURFACE.