Step 7 continued:
Connect temperature sensor leads as per diagram and tighten.
Ensure
there are no excess wires near the burners or draping on the heat shield.
Then
carefully lower the cook surface and push excess wire back through the heat shield so
there is a direct and straight path from the cook surface connection down through the heat
shield.
CONNECTING COOK SURFACE - ELECTRICAL CONNECTIONS 2 of 2
2
3
4
While one installer
supports cook surface,
the other installer
extends the TC wires up
through the heat shield
and connects to each
respective stud using
1/4 x 20 Hex Nuts. Hex
nuts only need moderate
tightening.
1
DO NOT OVER TIGHTEN TC-WIRE HEX NUTS. DOING SO WILL BREAK
THREADED WELD STUD ON COOK SURFACE.
WHEN LOWERING COOK SURFACE ENSURE ALL EXCESS WIRES ARE PUSHED
BACK THROUGH HEAT SHIELDS. NO WIRES SHOULD BE NEAR BURNERS OR
DRAPING ON HEAT SHIELDS.
Inner Zone
Outer Zone
Outer Zone
Outer Zone