Model 5601MSC
Model 5601MSC Master SPG/Master Clock System
Page - 8
Revision 2.2
OVERVIEW
The CompactFlash card can be removed by pressing the black eject button at the left side and pulling
the card out. New test pattern files can be written onto the CompactFlash by installing it into the
CompactFlash reader attached to any laptop or computer. The files can be copied into the
CompactFlash from the Evertz website. These test signal files are a custom Evertz .evt format. When
the CompactFlash is re-installed in the 5601MSC, it will automatically reload the test signals set. It is
not necessary to reboot or power off 5601MSC. Alternativly, test signal files can be upgraded using
FTP.
Figure 1-4: Front Panel Removed, CompactFlash Location
1.1.9.1. FTP Feature
To use this feature from a DOS command or Unix, enter
ftp IP
; where IP is the IP address of the
5601MSC, for example “
ftp 192.168.192.175
”. When promted to enter the user and password take the
following steps: for
User
press enter, and for
Password
use the password of the 5601MSC (Note: the
default is 5601). Either of the Ethernet ports may be used for FTP.
The following are commands to work with the FTP feature:
dir, send, get, delete
.
To send a test signal, enter
send filename filename
, for example
send ts1920smscHDq1.evt
ts1920smscHDq1.evt
.
FTP can also be used to upgrade the application.
To send the application, the ftp must be enabled. To do this enter
GENERAL
, then enter
Firmware
,
then enter
Enable FTP.
This will enable sending files to the 5601MSC for 15 minutes.
To send the application, enter
send filename a:\5601MSC.bin
. Where filename is the name of the file in
the computer, for example
send 5601MSC_2v5b4.bin A:\5601MSC.bin
. It is recommended to use the
hash command if in DOS command, to show activity. It will take about 6 seconds to send the
application. After it has been sent, enter
bye
to exit ftp.
At this time, the 5601MSC will store the downloaded file into its flash memory, and reboot. It will take
about 3 minutes to store the application. During this time,
DO NOT TURN OFF THE POWER TO THE
5601MSC
. If power is interrupted, the code will have to be reloaded via the com port. Progress can be
seen on the front panel
.
1.1.10. Configuring the Time Outputs
All time outputs from the unit come from the System Time clock. This clock can be viewed by pressing
the STATUS button and selecting the “System/LTC time” screen. When the time reference is obtained
from GPS or modem sources, the system time will be Coordinated Universal Time (UTC). UTC time is
the same at all locations around the world.
In order to output local time, the Time Zone must be selected to match the time zone offset of your
location. For example, in North America, Eastern Standard Time (EST) is UTC –5:00 hours. Central