MASTER CLOCK
the current MASTER stops sending announce messages for any reason. Good practice is to have them
set the same as all the other potential MASTERS.
Priority 1 is the first item in the BMC algorithm. It is usually set the same as all the other
potential MASTERS, but may be set lower to force this unit to become a MASTER, or lower to make
sure it is the last MASTER to be chosen.
Clock quality is the second item in the BMC algorithm. It is determined by reference type and
lock, and is not user settable.
Priority 2 is the third item in the BMC algorithm. It can be set higher or lower than other
MASTERS if there is a preference of MASTERS, given all other items are the same. If there is no
preference, set this to the same as the other potential MASTERS.
Domain must be set the same as all other MASTERS and SLAVES in the system. Any will only
look at packets from other devices on the same domain.
GMP enable is used to add a TLV to the announce message. It should only be enabled if there
is an Evertz GMP product in use. The Evertz product will get NTSC or PAL sync from this 5601MSC. It
should be set to the channel of sync that is providing this sync source. Note that the GMP must be
connected to this 5601MSC via an ordinary switch, or a transparent switch. It will not work through a
boundary switch.
.