Model 5601MSC
Model 5601MSC Master SPG/Master Clock System
Page - 124
Revision 2.2
MASTER CLOCK
4.4.4.4.12.
Selecting the Analog Video Test Generator Burn In Timecode Time Zone Offset
OUTPUT
This menu item allows the user to set a time zone offset between the
system time and the analog video test generator burn in time. The time zone
offset value is set in 30-minute increments. The system time should be
running at UTC. This time zone offset will be added to the system time
along with the Daylight Saving Time correction (see section 4.4.2.2.10) and
the analog video test generator burn in time frame offset (see section
4.4.2.2.8) to obtain the final SDI burn in time.
Use the
and
buttons or turn the control knob to move the cursor to
select the desired time zone offset. Press the
SELECT
button to choose the
indicated value. It will then become highlighted to show it is the active value.
ATG 1
Time zone
-12:00 hours
to
+12:00 hours
4.4.4.4.13.
Enabling Daylight Saving Time for the Analog Video Test Generator Burn in Clock
OUTPUT
This menu item allows the user to control whether the Daylight Saving Time
(DST) adjustment will be applied to the analog video test generator burn in.
When set to
Off
, Daylight Saving Time compensation will not be applied to
the SDI burn in time.
When set to
On
the rules set by the
DST rules
menu in the
GENERAL root
menu will be used to adjust the analog video test generator burn in time
(see section 4.5.9.5).
ATG 1
DST Ctl
Off
On
4.4.4.5. Setting the Analog Test Generator Syncro Mode
OUTPUT
This menu item controls the behaviour of the analog TG when the unit is
in syncro mode. If syncro is not enabled this menu item is ignored.
Select
Include syncro
to include the analog TG in the synchronization of
menu items between the master and slave units.
Select
Exclude syncro
to exclude the analog TG from synchronizing its
settings with the master or slave unit. This allows the TG to be modified
freely on the slave unit to different settings than the master.
ATG 1
Syncro
Include syncro
Exclude syncro
Содержание 5601MSC
Страница 2: ...This page left intentionally blank ...