background image

26

  |  

Safety Datasheet (SDS)  –  

Hazard Identification

Hazard Identification

Classification of the Hazardous Chemical:

 EXEMPT FROM CLASSIFICATION 

ACCORDING TO AUSTRALIAN WHS REGULATIONS.

Hazard Label: 

No signal word, pictogram, hazard, or precautionary statements have 

been allocated, but there is a label for 

Transport of Dangerous Goods

 on package. 

 

Class 9 – Lithium Batteries

Other Hazards:

 The product is equipped with a lithium iron phosphate battery, 

certified compliant under the UN recommendations on Transport of Dangerous Goods, 

Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.6/Amend 1. For the battery cell, 

the chemical materials are stored in a hermetically sealed metal case, designed to 

withstand temperatures and pressures encountered under normal operation. As a 

result, under normal operation there is no physical danger of ignition or explosion and/

or chemical danger of exposure to hazardous materials. The risk of exposure only 

occurs if the product is electrically, thermally (exposed to fire) or mechanically (severe 

shocks) abused. As a result, if the sealed metal case is breached, exposure to hazardous 

chemicals may occur by eye contact, skin contact and ingestion.

Composition/Information on Ingredients

Substances/Mixtures:

Chemical Name

Weight (%)

CAS #

Ethylene Carbonate (EC)

6.86

96-49-1

Graphite 

18.20

7782-42-5

Ethylene Carbonate (EC)

6.86

96-49-1

Ethyl Methyl Carbonate (EMC)

1.14

623-53-0

Diethyl Carbonate (DEC)

9.15

105-58-8

Propylene Carbonate (PC)

2.86

108-32-7

Lithium Hexafluorophosphate (LiPF6)

2.29

21324-40-3

Polypropylene

4.20

9003-07-0

Copper

1.68

7440-50-8

Aluminium

14.76

7429-90-5

Содержание AS1-3KS-10.2

Страница 1: ...User Manual AS1 3KS 5 1 B1 5 1 48 ENERGY VAULT...

Страница 2: ......

Страница 3: ...veready Brands LLC is affiliated with the respective owners of their trademarks To secure the full 7 year product warranty Eveready Energy Vault system must be commissioned using the Energy Vault MAX...

Страница 4: ...ii...

Страница 5: ...stem Monitoring 9 Eveready Energy Vault Web portal App 10 Maintenance 14 System Operation 16 System Connection Diagrams 18 Technical Resolutions 21 Emergency Procedures 22 Decommissioning and Recyclin...

Страница 6: ...ler The Energy Vault AS1 3KS 5 1 is a modular pre integrated battery energy storage system BESS used to harness electrical energy from solar photovoltaic systems Please note the following safety symbo...

Страница 7: ...on the Eveready Energy Vault system Do not mechanically damage the Eveready Energy Vault system by way of deforming piercing or stripping down The battery modules installed in the Eveready Energy Vaul...

Страница 8: ...o harsh chemicals or vapours Do not expose the Eveready Energy Vault system to temperatures in excess of 50 C If an Eveready Energy Vault system unit needs to be replaced or removed it must be turned...

Страница 9: ...at Do not touch the metal casing of the Eveready Energy Vault when it is running Attention Install the Eveready Energy Vault out of reach of children Refer to Error Codes Please refer to the error cod...

Страница 10: ...e primary unit AS1 3KS 5 1 can be used either in a stand alone manner or combined with a secondary unit B1 5 1 48 allowing a wide range of energy storage options Each primary unit can be associated wi...

Страница 11: ...ave a unique serial number which can be described as follows AS1 represents the product series XK refers to the rated power of the product X kW such as 3K for 3kW S represents single phase XX refers t...

Страница 12: ...and discharge the battery and relies on Current Transformers CTs to measure solar generation and grid based consumption The below image covers the key elements of the Eveready Energy Vault system It c...

Страница 13: ...mode is designed to allow users to benefit from energy arbitrage Users can set the battery to charge and discharge during specific times of the day when energy prices are low or high thereby enabling...

Страница 14: ...nvection Ambient Humidity 0 95 Non condensing Noise dBA 29 Ingress Protection IP65 Inverter Parameters Max Grid Back Up Power VA 3000 N A Max Grid Back Up Current A 13 1 N A Rated Grid Back Up Voltage...

Страница 15: ...with custom flashing lights based on battery operation The various battery operations are covered in Table 3 Additional control and monitoring features are also available via the Eveready Energy Vault...

Страница 16: ...r Eveready Energy Vault registration as they may have a customised process If your system provider wants you to register the plant yourself please follow the below steps Open the Eveready Energy Vault...

Страница 17: ...ly monthly yearly and total energy usage Definitions Self consumption is the component of solar generation that is used locally on site Self consumption rate is the percentage of solar generation that...

Страница 18: ...dy Energy Vault AS1 system Chart Click Chart at the bottom of the home page to view the statistical information Toggle the energy graph between Day Month Year and Total to view the historical data cor...

Страница 19: ...uires a reliable internet connection for the purpose of monitoring and enables over the air updates to be conducted to improve system performance and longevity Extended interruptions or inability to m...

Страница 20: ...m the End User For accumulation of dirt dust or debris please ensure the product frame and LED Status Indicators are cleaned using a soft dry cloth Do not use any cleaning agents as they may damage th...

Страница 21: ...rm 54 Low battery SoC alarm master Alarm 55 Voltage of battery high alarm master Alarm 56 Voltage of battery low alarm master Alarm 57 Voltage of grid high warning slave Alarm 58 Voltage of grid low w...

Страница 22: ...nergy Vault includes a combination of primary and secondary unit s the system shall be turned off as follows 1 If Back Up UPS loads are connected turn off respective AC circuit breakers a If applicabl...

Страница 23: ...AS1 system C20 a If applicable turn on any circuit breaker connected on the grid side 2 Turn on the DC switches for the Eveready Energy Vault in a bottom up sequence These are located on the right ha...

Страница 24: ...ystem shall be configured as per the site s energy requirements As specified in Section 4 each primary unit AS1 3KS 5 1 can be installed either in a stand alone manner or combined with up to 3 seconda...

Страница 25: ...nection is single phase the system shall employ a combination of CTs Grid and PV CTs to measure relevant grid import export and solar generation data The system is connected as per the below schematic...

Страница 26: ...phase service connection it shall employ digital meters to measure grid import export and solar generation The system is connected as per the below schematic Note the Back Up UPS feature is applicabl...

Страница 27: ...is not operating correctly or a fault alarm persists contact your Eveready Energy Vault system provider Always ensure that your Eveready Energy Vault AS1 system is connected to the internet and you h...

Страница 28: ...cohol resistant foam extinguishers Do not use water jets or streams as it may scatter or spread chemicals Smoke or Unusual Smells Turn off all Battery System Isolators on the AS1 and B1 units Turn off...

Страница 29: ...eyelids Seek medical attention if eye irritation persists Skin Remove contaminated clothes and rinse skin with plenty of water or shower for 15 minutes Seek medical attention if skin irritation persi...

Страница 30: ...the batteries must be recycled in accordance with local and federal laws and regulations through licensed waste carriers and or suitable recycling facilities etc Eveready advocates for recycling of t...

Страница 31: ...Identified Uses Intended to be used as an AC coupled Battery Energy Storage System Use Restrictions Operate the battery under the following conditions Temperature Range 0 C to 50 C Operating Temperat...

Страница 32: ...temperatures and pressures encountered under normal operation As a result under normal operation there is no physical danger of ignition or explosion and or chemical danger of exposure to hazardous ma...

Страница 33: ...r seek medical aid by calling a physician for appropriate medical advice Symptoms Caused by Exposure Adverse effects are not expected to occur from being exposed to this product Long term exposure may...

Страница 34: ...28 Safety Datasheet SDS First Aid Measures...

Страница 35: ...hazardous chemical disposal authority Handling and Storage Precautions for Safe Handling and Storage The batteries should not be opened destroyed or incinerated as they are susceptible to leak or rup...

Страница 36: ...ical Properties Appearance Lithium Ion batteries enclosed within protective metal case Odour If leakage is detected smells of medical ether Flash Point No information available Melting Point or Freezi...

Страница 37: ...d or discharged they can be considered a reactive hazardous waste The batteries must be disposed of in accordance with local and federal laws and regulations through licensed waste carriers and or sui...

Страница 38: ...ducts It only applies where Products have been installed correctly by a certified installer CEC approved according to the Product s Installation Manual This Warranty is non transferable to any third p...

Страница 39: ...the invoice date or for a minimum total output energy which is calculated from the date of commissioning whichever comes first Test Conditions for Capacity Performance Environment Condition Ambient te...

Страница 40: ...to SolarBOS within 2 weeks of appearance with all related information 2 7 The Product must have its original serial number and rating labels intact and readable 2 8 End User must provide proof of the...

Страница 41: ...air may be replaced with an equivalent refurbished Product instead of being repaired If your Product is repaired or replaced under this Warranty then the repaired or replaced Product will benefit from...

Страница 42: ...the Product for climate or other environmental influence foreign material contamination e g smoke salt and chemicals etc water entry exposure to excessive heat or solvents or because of use of the Pr...

Страница 43: ...Process Step by step Step 1 End User shall gather proof of purchase such as commercial invoice Step 2 At the time of a Warranty Claim fill in the Warranty Card Step 3 Contact SolarBOS and share all r...

Страница 44: ...nable costs associated with the making of a Warranty Claim including Warranty processing costs the cost of replacement parts or freight and labour cost associated with the Products removal and install...

Страница 45: ...ge of the matter of event giving rise to the claim No consideration will be given to claims under this Warranty which are made after this period Product Liability and Product Safety We should be infor...

Страница 46: ...e within applicable laws and shall be under mandatory application according to applicable law No distributor agent or staff of SolarBOS and or Eveready Certified Distributors is authorised to make any...

Страница 47: ...ods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Non applicability of Warranty Claim If the claimants do not comply with the ab...

Страница 48: ......

Страница 49: ...sioning Checklist Following the installation of the Eveready Energy Vault AS1 3KS 5 1 B1 5 1 48 ensure that you complete the below checklist and share a record with your system provider It is also rec...

Страница 50: ...on Customer Name Date Address 2 System Provider Contact Details Provider Name Contact Number 3 Eveready Energy Vault Model No AS1 3KS 5 1 AS1 3KS 10 2 AS1 3KS 15 3 AS1 3KS 20 4 AS1 3KS 5 1 Primary Uni...

Страница 51: ...e Device info page Local Connection Device commissioning Device info Basic info Module version Display version Control version BMS Software version BMS Hardware version 8 Verification Normal System Op...

Страница 52: ...system provider basic system opperation and design principles Further ensure that a copy of the below customer acknowledgement is provided to the system provider for installation records Customer Ackn...

Страница 53: ...y Energy Vault Model No AS1 3KS 5 1 AS1 3KS 10 2 AS1 3KS 15 3 AS1 3KS 20 4 DVC Level DVC A Battery Battery Product Type as per AS NZS 5139 2019 CEC Approved BESS Assessed by Date of Assessment Reviewe...

Страница 54: ...r insulation some parts of a BS may remain energised INCIDENT ENERGY CALCULATION 1 94 cal cm2 NOTE See Table G5 of AS NZS 5139 2019 Clause 3 2 4 2 1 to determine arc flash incident energy burns to eye...

Страница 55: ...ological hazards See Table 3 1 of AS NZS 5139 5 Low 5 Explosive gas hazards Explosive gas generated by batteries inadvertent ignition of flammable gas Burns to eyes and skin secondary injuries as a re...

Страница 56: ...teries containing alkaline or other non acid electrolytes Safety requirements for secondary lithium cells and batteries for use in industrial applications standards The battery cells and modules are s...

Страница 57: ...Notes...

Страница 58: ......

Страница 59: ......

Страница 60: ...www evereadysolarstorage com ENERGY VAULT...

Отзывы: