![EVBox BusinessLine Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/evbox/businessline/businessline_installation-and-commissioning-manual_2441701023.webp)
MCB
(Miniature
Circuit
Breaker)
16 A installation: use a 20 A MCB, C-characteristic.
32 A installation: use a 40 A MCB, C-characteristic.
Note:
• A MCB is only required for a charging station without RCBO.
• The MCB should match the amperage settings of the charging station
and the maximum current available for the station, considering MCB
manufacturer specifications.
• Consider the availability of additional sources of power (for example
solar) together with a dynamic load balancing system (optional).
RCD
(Residual
Current
Device)
40 A, 30 mA AC type A.
BusinessLine
has a 6 mA DC leakage detection
internally.
Note:
• A RCD is only required for a charging station without RCBO.
Note:
For a TT or IT electric grid with 230 V from line to line, the charging station must be installed
with one phase being connected to terminal L1 and the other phase being connected to
terminal N.
Power supply wiring
The table below shows how to connect the power supply to BusinessLine, depending on the
specifications of the power supply cabinet and the version of BusinessLine.
Option 1: 400 V 3-phase with neutral
For 3-phase use of a Wye-connected secondary, all three
phases (L1, L2 and L3) and neutral must be connected.
Each phase voltage must measure 230 V to neutral.
4. Installation instructions
EN
19
Содержание BusinessLine
Страница 1: ...EVBox BusinessLine Installation and commissioning manual Part A 1...
Страница 2: ......
Страница 3: ...EVBox BusinessLine Installation and commissioning manual Part A...
Страница 4: ......
Страница 43: ...The Netherlands www evbox com support 6 Appendix EN 39...
Страница 44: ...EN 6 Appendix 40...
Страница 45: ......
Страница 46: ...EVBIM_072021 EVBox Manufacturing B V...