E-S 500 / 502 Classic Series Instruction Manual
4.4
Operating Parameters Customization
1. LED shows P1:
P1 is for setting your run time
. The run time will be determined from the
time you had determined during the set up of the limit switches. Take that determined
run time and add 1 second. So if it takes 10 seconds to get from closed to open be-
tween limit switches; set the run time to 11 seconds. The options are 0-99 seconds.
2. LED shows P2:
P2 is for setting your slow down time
. The gate opener will slow down
to half speed after the time set on P2 expires. If you wish to have the gate open and
close faster make the slow down start time a longer period of time. If you want to put
less stress on the gears and gate set the slow time shorter to slow the momentum soon-
er. The options will adjust to match the previously set run time. NOTE:
motor must be in
slow down to detect limits—be sure this number does not exceed the time the motor
take to move from one limit to the other.
3. LED shows P3:
P3 is the force setting
, the lower the number the easier the gate will re-
verse directions when it meets resistance. This number may have to be changed to a
higher setting if your gate is obstructing unexpectedly. The number should be set to the
highest number during initial setup and reduced to the point of reliable operation that
takes into account change in gate resistance through out the year. The options are 0-
32.
4. LED shows P4:
P4 is for setting a delay between leafs
if you have overlapping gates or
a gate lock. The motor wired into the master terminals (1) opens first if there is a delay
and closes second. It is recommended to have a delay of 3 seconds to avoid any jam-
ming issues between leafs.
5. LED shows P5:
P5 is the release for the gate lock
– this option determines the length of
time 24VDC will be sent out of terminals E_LOCK. The options are 1-4 seconds.
6. LED shows P6:
P6 is the delay for automatic re-close
from the open position – this op-
tion needs to be turned on using the dip switch on the board. The options are 0-99 sec-
onds.
Содержание E-S 500
Страница 4: ...E S 500 502 Classic Series Instruction Manual SECTION 1 Review of Specifications Warnings and Tools ...
Страница 5: ......
Страница 10: ...E S 500 502 Classic Series Instruction Manual SECTION 2 Installation of Mounting Brackets ...
Страница 11: ......
Страница 25: ...E S 500 502 Classic Series Instruction Manual SECTION 3 Gate Operator Mounting Wiring Motors Power ...
Страница 26: ......
Страница 36: ...E S 500 502 Classic Series Instruction Manual SECTION 4 Start Up and Operation ...
Страница 37: ......
Страница 44: ...E S 500 502 Classic Series Instruction Manual SECTION 5 Maintenance Troubleshooting Accessories ...
Страница 45: ......