![Esko Kongsberg V-Series Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/esko/kongsberg-v-series/kongsberg-v-series_user-manual_2427108069.webp)
12
Kongsberg V-series
Chuck Open/Close valve operation
Never operate the
Chuck Open/Close valve
while the spindle is running.
This will destroy
the spindle.
Air Pressure and Quality
Never run IBAG spindle with
Pressurized Air
disconnected.
This may destroy the spindle.
Keep this in mind also for test purposes.
Use clean air
Never run IBAG spindle with
Pressurized Air
disconnected.
This will destroy the
Spindle
.
Use Clean Air
The
Spindle
is sensitive for the
Pressurized
Air
quality.
Regularly check the
Air Pressure Reduction
Valve
according to the
Maintenance
on page
129 section.
Maintain bit clamping
Un-proper
bit clamping
may cause the bit to
slip in the
chuck
and damage the
Table Top
.
1.
Keep the
bit shaft
clean.
2.
Avoid greasy fingers.
3.
Clean the
bit shaft
with acetone if
necessary, but use only dry cotton tips on
the chuck.
4.
Maintain
Pressurized Air
supply of 7 bar.
5.
Follow procedures strictly:
Chuck Change
and Cleaning
on page 76.
69