During normal operation, the cooling medium temperature is displayed.
If any chiller failure occurs:
• Alarm signal is generated.
• Chiller will stop.
• Look at the chiller display to see the real reason for the problem:
Code
Description
AL
Water level or water flow too low. Check for correct water level in the
Water Level Indicator on Chiller front.
H1
Temperature of cooling medium too high, > 35
o
C / 95
o
F
L1
Temperature of cooling medium too low, < 19
o
C / 66
o
F
Continue after error situation
• Find root cause for the error situation and fix it. Flow too low is normally caused by a
squeezed water hose.
• Switch chiller unit OFF and ON again.
More information is available from the Operating instructions for the chiller.