![Esko Kongsberg V-Series Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/esko/kongsberg-v-series/kongsberg-v-series_user-manual_2427108038.webp)
8
Kongsberg V-series
• Press the
Measure Tool
button.
• A wizard dialog appears.
• Follow the instructions in the wizard to complete calibration.
•
Height Settings
Current setting: The automatically measured height value.
•
Automatic Measurement Adjustment
New offset setting:
Use this value to modify the height measured by the
Measuring Pad
. Negative value
means down into the material.
Current offset setting:
The initial offset value (when the dialog was opened) is displayed.
How to start a measuring sequence in the middle of a job
Two methods are available:
1.
Measure after
Stop at Tool Select
(Stop before use). The execution will stop for each tool
change and a tool height measuring sequence can be carried out.
2.
You press
Pause
.
In both cases the tool height measuring sequence should be started from the
Operators
Panel
as described above.
How to cancel measuring or calibration