SmartEdge 600 Router Hardware Guide
Table 47
Output Fields for the show port Command with the transceiver Keyword - for SFP
or XFP Transceiver Port Data
State
Description
SFP Transceivers—Ethernet line cards:
• FX / MM—Short reach transceiver, multimode fiber.
• LX10 / SM—Long reach transceiver, single-mode fiber.
• SX / MM—Short reach transceiver, multimode fiber.
• LX / SM—Long reach transceiver, single-mode fiber.
• ZX / SM—Extended long reach transceiver, single-mode fiber.
• T / Cat5—Copper-based transceiver.
• CWDM / SM—Coarse wavelength-division multiplexing (CWDM) transceiver, single-mode fiber.
• DWDM / SM—Dense wavelength-division multiplexing (DWDM) transceiver, single-mode fiber.
SFP / Media type
SFP transceivers—SONET OC-n (OC-3c/STM-1c, OC-12c/STM-4c, and OC-48c/STM-16c) cards:
• SR / SM—Short reach transceiver, single-mode fiber.
• SR / MM—Short reach transceiver, multimode fiber.
• IR / SM—Intermediate reach transceiver, single-mode fiber.
• LR / SM—Long reach transceiver, single-mode fiber.
XFP / Media type
10-Gbps SFP (XFP) transceivers—OC-192 and 10-Gig Ethernet line cards:
• SR / SM—Short reach transceiver, single-mode fiber.
• SR / MM—Short reach transceiver, multimode fiber.
• IR / SM—Intermediate reach transceiver, single-mode fiber.
• LR / SM—Long reach transceiver, single-mode fiber.
• ER / SM—Extended long reach transceiver, single-mode fiber.
• ZR / SM—Extreme reach transceiver, single-mode fiber.
(1)
• DWDM / SM—Dense wavelength-division multiplexing (DWDM) transceiver, single-mode fiber.
(2)
Redback Approved
State of transceiver testing for transceiver in SmartEdge routers:
• No—Not tested.
• Yes—Tested.
Diagnostic monitoring
Whether the installed transceiver supports diagnostic monitoring compliant to SFF-8472 for SFPs
or INF-8077i for XFPs.
Serial number
nnnnnnnnnnnnnn—Unique identifier for this transceiver.
Wavelength
Center wavelength for the version of the optical transceiver installed in this port:
• 0.00 [nm]—Wavelength is not reported by this transceiver.
• nnnn.nn [nm]—Wavelength for this transceiver version.
Tx Pwr [dbm]
(3)
Transmitter optical output power (measured, minimum, and maximum limits) for the version of
the transceiver installed in this port.
Rx Pwr [dbm]
Receiver sensitivity (measured, minimum, and maximum limits) for the version of the transceiver
installed in this port.
Temperature [oC]
Temperature (measured, minimum, and maximum limits) in degrees Centigrade.
70
27/153 30-CRA 119 1170/1 Uen A
|
2010-04-09
Содержание SmartEdge 600
Страница 1: ...SmartEdge 600 Router Hardware Guide Release 6 3 INSTALLATION 27 153 30 CRA 119 1170 1 Uen A ...
Страница 6: ...SmartEdge 600 Router Hardware Guide 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Страница 26: ...SmartEdge 600 Router Hardware Guide 20 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Страница 108: ...SmartEdge 600 Router Hardware Guide 102 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Страница 112: ...SmartEdge 600 Router Hardware Guide 106 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...