SmartEdge 600 Router Hardware Guide
Table 62
Optical Port Alarms—Line/Multiplex Section Layer
Description
Severity
Probable Cause
Service Affecting
Line alarm indication signal (AIS-L)
Minor
AIS
No
Line remote failure indication (RFI-L)
Minor
FarEndReceiverFailure
No
Line signal degrade (BER)
Major
DegradedSignal
Yes
Line signal failure (BER)
Major
ExcessiveBER
Yes
Lockout protection requested
Major
OperationNotification
Yes
Lockout working requested
Major
OperationNotification
Yes
Loss of clock
Major
LossOfTimingSource
Yes
Port auto switch completed
Major
OperationNotification
Yes
Port channel mismatch
Major
ApsChannelMatchFailure
Yes
Port diagnostic failed
Major
ReplaceableUnitProblem
Yes
Port far-end protection line failure
Major
ApsChannelProcessingFailure
Yes
Port fault oscillations detected
Critical
DegradedSignal
Yes
Port forced switch requested
Major
OperationNotification
Yes
Port manual switch request
Major
OperationNotification
Yes
Port mode mismatch
Major
ApsModeMismatch
Yes
Port payload loopback enabled
Minor
OperationNotification
No
Port protection switch byte failure
Major
ApsByteFailure
Yes
Port switch completed
Major
OperationNotification
Yes
Port switch failed
Major
OperationFailure
Yes
Port switch lockout requested
Major
OperationNotification
Yes
Port switch protection path failure
Major
OperationFailure
Yes
Port switch waiting to restore
Minor
OperationNotification
No
Table 63
SFP Transceiver Alarms
Description
Severity
Probable Cause
Service Affecting
Transceiver receive power–high
Major
Replaceable Unit Problem
Yes
Transceiver receive power–low
Major
Replaceable Unit Problem
Yes
Transceiver TX power–high
Major
Replaceable Unit Problem
Yes
Transceiver TX power–low
Major
Replaceable Unit Problem
Yes
Transceiver temperature–high
Major
Replaceable Unit Problem
Yes
Transceiver temperature–low
Major
Replaceable Unit Problem
Yes
Transceiver bias current–high
Major
Replaceable Unit Problem
Yes
Transceiver bias current–low
Major
Replaceable Unit Problem
Yes
Transceiver receive power–high warning
Minor
Replaceable Unit Problem
No
Transceiver receive power–low warning
Minor
Replaceable Unit Problem
No
Transceiver TX power–high warning
Minor
Replaceable Unit Problem
No
78
27/153 30-CRA 119 1170/1 Uen A
|
2010-04-09
Содержание SmartEdge 600
Страница 1: ...SmartEdge 600 Router Hardware Guide Release 6 3 INSTALLATION 27 153 30 CRA 119 1170 1 Uen A ...
Страница 6: ...SmartEdge 600 Router Hardware Guide 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Страница 26: ...SmartEdge 600 Router Hardware Guide 20 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Страница 108: ...SmartEdge 600 Router Hardware Guide 102 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...
Страница 112: ...SmartEdge 600 Router Hardware Guide 106 27 153 30 CRA 119 1170 1 Uen A 2010 04 09 ...