Servicing Hardware
2.
Slide the module from the shelf.
To replace the AC power module:
1.
Open the front ejector (fan cover) of the power module by squeezing the
latch spring and pulling open the ejector.
Figure 33
Inserting an AC Power Module
2.
Insert a module into one of the two center slots (2 and 3) in the shelf.
3.
Push the module in until the right side of the ejector engages the receptacle
slot in the shelf wall.
4.
Push closed the ejector lever until the module spring latch locks on the
ejector to seat the module.
101
27/153 30-CRA 119 1170/1 Uen A
|
2010-04-09